Section 3 – SR-2 Software Description
Electric to Diesel Auto Switch Enabled?
Micro Rev
All
HMI Rev
All
Choices
YES or NO
Factory Set
NO
Exceptions
Description
This feature allows the Auto Switch
from Electric to Diesel to be enabled or disabled. If
this feature is set YES, the unit will switch
automatically to diesel mode when standby power is
disconnected or fails. If the feature is set NO, the
operator must physically switch the unit to diesel
mode.
SL Unit?
Micro Rev
All
HMI Rev
All
Choices
YES or NO
Factory Set
To match unit as built
Exceptions
Description
SL units should be set YES. All
other units should be set NO.
High Capacity Unit?
Micro Rev
All
HMI Rev
All
Choices
YES or NO
Factory Set
To match unit as built
Exceptions
Description
If the unit was built as a high
capacity unit (2600 RPM high speed), this setting
should be set to YES to allow the engine to run at
higher rpm in high speed. If the unit was not built as
a high capacity unit this setting must be set to NO.
High Capacity Fresh Is?
Micro Rev
All
HMI Rev
All
Choices
YES or NO
Factory Set
NO
Exceptions
Available only if the high capacity
option is selected.
Description
If the unit was built as a high
capacity unit, this setting should be set to YES to
allow the engine to run at higher rpm (1730 rpm) in
low speed. If the unit was not built as a high
capacity unit this setting must be set to NO.
Defrost Motor Equipped?
Micro Rev
All
HMI Rev
All
Choices
YES or NO
Factory Set
To match unit as built
Exceptions
Description
This feature specifies if the unit is
equipped with a defrost solenoid or defrost motor. If
the unit is equipped with a defrost motor this feature
should be set Yes. If the unit is not equipped with a
defrost motor this feature should be set No.
NOTE: All SL-400e units are equipped with defrost
motors and this feature must be set YES.
NOTE: A different interface board is required for
units equipped with a damper gear motor. The
damper gear motor interface board has added
electronic circuitry to drive the gear motor.
Fuel Sensor Type
Micro Rev
All
HMI Rev
All
Choices
NONE, SOLID STATE or FLOAT
Factory Set
NONE
Exceptions
Description
This feature is used to select the
type of fuel level sensor installed, either float type or
solid state type. If no fuel level sensor is installed,
this feature should be set to NONE.
3-45
31 January 2005
Summary of Contents for SR-2 SmartReefer2
Page 4: ......
Page 7: ...Tab goes here and the next page should be GREEN Section 1 Safety...
Page 8: ......
Page 10: ...Section 1 SR 2 Safety Information 1 2 18 January 2005...
Page 14: ...Section 1 SR 2 Safety Information 1 6 18 January 2005...
Page 15: ...Tab goes here and the next page should be GREEN Section 2 Hardware Description...
Page 16: ......
Page 48: ...Section 2 SR 2 Hardware Description 2 32 31 January 2005...
Page 49: ...Tab goes here and the next 2 pages should be GREEN Section 3 Software Description...
Page 50: ......
Page 96: ...Section 3 SR 2 Software Description 3 46 31 January 2005...
Page 97: ...Tab goes here and the next page should be GREEN Section 4 Operation...
Page 98: ......
Page 181: ...Tab goes here and the next 2 pages should be GREEN Section 5 Diagnostics...
Page 182: ......
Page 266: ...Section 5 SR 2 Diagnostics 5 84 02 February 2005...
Page 267: ...Tab goes here and the next page should be GREEN Section 6 Service Procedures...
Page 268: ......
Page 270: ...Section 6 SR 2 Service Procedure Index Page 2 01 February 2005...
Page 282: ...Section 6 SR 2 Service Procedure A01B Page 6 P41RA01B 31 January 2005...
Page 298: ...Section 6 SR 2 Service Procedure A02A Page 12 P41RA02A 02 February 2005...
Page 318: ...Section 6 SR 2 Service Procedure A03B Page 4 P41RA03B 30 January 2005...
Page 338: ...Section 6 SR 2 Service Procedure A15A Page 4 P41RA15A 30 January 2005...
Page 360: ...Section 6 SR 2 Service Procedure A46B Page 8 P41RA46B 30 January 2005...
Page 366: ...Section 6 SR 2 Service Procedure A48A Page 6 P41RA48A 30 January 2005...
Page 376: ...Section 6 SR 2 Service Procedure A50A Page 6 P41RA50A 31 January 2005...
Page 394: ...Section 6 SR 2 Service Procedure F08A Page 4 P41RF08A 30 January 2005...
Page 398: ...Section 6 SR 2 Service Procedure F09A Page 4 P41RF09A 30 January 2005...
Page 402: ...Section 6 SR 2 Service Procedure G03A Page 4 P41RG03A 31 January 2005...
Page 406: ...Section 6 SR 2 Service Procedure H04A Page 4 P41RH04A 30 January 2005...
Page 407: ...Tab goes here and the next page should be GREEN Section 7 Service Information...
Page 408: ......
Page 410: ...Section 7 SR 2 Information 7 2 02 February 2005...
Page 419: ...Tab goes here and the next page should be GREEN Section 8 Schematics and Wiring Diagrams...
Page 420: ......
Page 422: ...Section 8 SR 2 Drawings 8 2 01 February 2005...
Page 424: ...Section 8 SR 2 Drawings 8 4 01 February 2005...
Page 425: ...8 5...
Page 426: ...8 6...
Page 427: ...8 7...
Page 428: ...8 8...
Page 429: ...8 9...
Page 430: ...8 10...
Page 431: ...8 11...