Operating Instructions
76
Alarms:
The Alarm Menu allows the operator to view any
active alarms, and allows most alarms to be cleared.
Gauges:
The Gauges Menu allows the operator to view the
unit gauges and I/O conditions.
Sensors:
The Sensors Menu allows the operator to view the
unit and CargoWatch Data Logger temperature sensors.
Data Logger (CargoWatch):
The CargoWatch Data Logger
is physically located in the HMI Control Panel. It can support
up to 6 optional temperature sensors.
Hourmeters:
The Hourmeters Menu allows the operator to
view the unit hourmeters that have the view feature enabled in
the Guarded Access menu.
Mode:
The Mode Menu allows the operator to change the unit
operating modes that have been enabled in Guarded Access.
Keypad Lockout:
If enabled in Guarded Access > Main
Menu Configuration, the keypad can be locked to prevent
unauthorized use.
Start Sleep Mode:
If this feature enabled in Guarded Access
> Main Menu Configuration, the operator can select and set
Sleep Mode from the Mode Menu.
SmartPower™ Electric Standby Option:
The
Diesel/Electric Standby selection from the Main Menu allows
the operator to manually select Diesel or Electric Mode
operation on units equipped with the electric standby
SmartPower option.
Adjust Brightness:
The brightness of the HMI Control
Panel display can be adjusted to allow for changing ambient
light conditions.
Time:
The Time and Date held by the HMI Control Panel can
be checked. Time and Date cannot be changed from the Main
Menu.
Clear All ECU Faults:
Pressing this key will clear all
existing Engine Control Unit (ECU) Fault Codes.
Pretrip
Pretrip Test verifies unit operation. This display allows a
Pretrip Test to be selected and initiated by the operator. If the
Pretrip Test is entered with the unit shut down a Full Pretrip
Test with device amp checks will be performed. If the Pretrip
Test is entered with the unit running in either Diesel or Electric