Operating Instructions
62
Switching from Diesel to Electric
Units equipped with the SmartPower option only.
If the Diesel to Electric Auto-Switch Enabled feature in
Guarded Access is set YES then the unit will automatically
switch to Electric Mode operation when standby power is
connected and available.
If the Diesel to Electric Auto-Switch Enabled feature in
Guarded Access is set NO then the prompt screen (Figure 59)
will appear when standby power is connected and available.
Figure 59: Standby Power Connected
If NO is selected, then the unit will continue to operate in
Diesel Mode. If YES is selected then the display will briefly
show the screen in Figure 60.
Figure 60: YES Selected
Electric Mode operation will briefly be confirmed. If unit
operation is required the electric motor will start as shown
previously under STARTING THE ELECTRIC MOTOR.
If the Diesel to Electric Auto-Switch Enabled feature in
Guarded Access is set NO then the unit can also be switched
from Diesel Mode to Electric Mode operation using the
Electric Standby Selection from the Main Menu as shown later
in this section.
ON
OFF
ELECTRIC STANDBY DETECTED
DO YOU WISH TO SWITCH TO
ELECTRIC?
NO
YES
PROGRAMMING ELECTRIC
STANDBY
PLEASE WAIT
ON
OFF