Alarm Codes
143
corrective action before a problem becomes severe.
Maintenance items such as a maintenance reminder hour meter
reaching its time limit are log alarms.
Figure 184: Log Alarms Screen
Check Alarms:
Check Alarms are indicated by the Alarm
Display in which the large Alarm Icon will appears on the
Standard Display as shown below in Figure 185. The Alarm
Menu must be used to view the existing alarms. This level of
alarm serves as a notice to take corrective action before a
problem becomes severe. The unit will run with check alarms
but some features and functions may be inhibited.
Figure 185: Alarm Display
Prevent Alarms:
Prevent Alarms are also indicated by the
Alarm Display as shown in Figure 185. The Alarm Menu must
be used to view the existing alarms. The unit may stop running
and wait a timed interval or until conditions allow and then
restart. If the unit is waiting to restart, Alarm Code 84 Restart
Null will be present along with the Prevent Alarm. In other
cases the unit may restart or run with reduced performance to
determine if continued operation is possible. If the alarm does
not reoccur with reduced performance the unit will then return
to full performance. If the unit is operating with reduced
performance Alarm Code 85 Forced Unit Operation will also
be present.