Alarm Codes
144
Shutdown Alarms:
Shutdown Alarms are indicated by the
Alarm Display. Shutdown alarms also cause the display and
backlight to flash on and off, and the display will switch from
normal video to reverse video and back to normal video (light
areas become dark and dark areas become light as shown in
Figure 186). Shutdown alarms force the unit into shutdown.
The unit will remain in shutdown and will not restart until the
shutdown alarm is cleared. Exceptions are some engine and
electric shutdown alarms become that log alarms when
switched to the alternate operating mode (diesel to electric or
electric to diesel).
If a shutdown alarm occurs that affects only Diesel Mode
operation and the unit is switched to electric (either manually
or automatically), the Diesel Mode shutdown alarm becomes
an Electric Mode log alarm. This allows the unit to run in
Electric Mode without clearing the shutdown alarm that is
preventing Diesel Mode operation. If the unit is switched back
to Diesel Mode, the alarm again becomes a Diesel Mode
shutdown alarm and prevents unit operation. If the unit is
configured for electric to diesel autoswitch, it automatically
starts and runs in Diesel Mode if an electric shutdown occurs.
In the same manner, if a shutdown alarm occurs that affects
only Electric Mode operation and the unit is switched to diesel
(either manually or automatically), the Electric Mode
shutdown alarm becomes a Diesel Mode log alarm to allow
Diesel Mode operation. If the unit is switched back to Electric
Mode, the alarm reverts to an Electric Mode shutdown alarm
and prevents unit operation.
Figure 186: Shutdown Alarm Display
Pretrip Alarm Codes
If an alarm occurs during a Pretrip Test the alarm code will be
displayed as Pretrip Alarm XX, where XX is the alarm code.