Optional Rear Remote Control Panel
126
Reading a Typical Remote
Standard Display
The Remote Standard Display shows the temperature and
setpoint. The icons at the sides of the display indicate operating
conditions.
Figure 161: Remote Standard Display
The Remote Standard Display in Figure 161 shows the
following information:
•
The temperature (typically return air temperature) is
35.8°F.
•
The setpoint is 35°F.
•
The unit is cooling as shown by the icon at the upper left
side of the display.
•
The unit is operating in Cycle Sentry mode as shown by
the icon at the upper right side of the display.
Remote Control Panel Lockout
The remote control panel may be locked out during some
control system functions such as Service Test Mode, Interface
Board Test Mode and while setting programmable features. If
this is the case the display shown in Figure 162 will appear.
The display will return to the Remote Standard Display when
allowed by the control system.
Figure 162: Remote Lock Out Display