46
4-11-5. :SYSTem:CONFigure:VOLTage:CONTrol
Set
Query
Description
Sets or queries the CV control mode (local control, external
voltage control, external resistance control). (F-90)
This setting is applied only after the unit is reset.
Syntax
SYSTem:CONFigure:VOLTage:CONTrol
{<NR1> | NONE | VOLTage | RRISing | RFALling}
Query Syntax SYSTem:CONFigure:VOLTage:CONTrol?
Parameter
<NR1>
Description
0 / NONE
Local (Panel) control
1 / VOLTage External voltage control
2 / RRISing External resistance control;
10k
Ω = Vo max, 0kΩ = Vo min.
3 / RFALling External resistance control;
10kΩ = Vo min, 0kΩ = Vo max.
Example
:SYST:CONF:VOLT:CONT 0
Sets the setting state of the CV control mode.
Query
example
:SYST:CONF:VOLT:CONT?
>0
Return the setting state of the CV control mode.
4-11-6. :SYSTem:CONFigure:OUTPut:PON
[:STATe]
Set
Query
Description
Sets the output state at power-on. This is the equivalent to the
F-92 (Output Status when Power ON) power on configuration
settings. These settings only apply after the unit has been reset.
Syntax
:SYSTem:CONFigure:OUTPut:PON[:STATe]
{<NR1> | {SAFE | OFF} | {FORCe | ON} | AUTO}
Query Syntax :SYSTem:CONFigure:OUTPut:PON[:STATe]?
Parameter
0 / SAFE |
OFF
The PFR-100 turns on in the same state the unit was
in prior to the previous shut down. The output is set
to off (default).
1 / FORCe
| ON
The PFR-100 turns on in the same state the unit was
in prior to the previous shut down. The output is set
to on.
2 | AUTO
The PFR-100 turns on in the same state the unit was
in prior to the previous shut down, but with the same
output on/off setting.
Return
parameter
0
The power on output setting is
“
SAFE” or “OFF”.
1
The power on output setting is
“
FORCe” or “ON”.
2
The power on output setting is
“
AUTO”.
Example
:SYST:CONF:OUTP:PON 1
The power on output setting is on.