39
Query
example 2
:CURR:PROT? MIN
>+0.200
Returns the minimum OCP level.
4-10-6. [:SOURce]:CURRent:PROTection:TRIPped
Query
Description
Returns the state of the OCP.
Query Syntax [:SOURce]:CURRent:PROTection:TRIPped?
Return
parameter
<Boolean>
0
The OCP has not been tripped.
1
The OCP has been tripped.
Query
example
:CURR:PROT:TRIP?
>0
The OCP has not been tripped.
4-10-7. [:SOURce]:CURRent:SLEWrate:RISing
Set
Query
Description
Sets or queries the rising current slew rate. This is only applicable
for CC slew rate priority mode.
Syntax
[:SOURce]:CURRent:SLEWrate:RISing {<NRf>|MINimum |
MAXimum}
Query Syntax [:SOURce]:CURRent:SLEWrate:RISing? [MINimum | MAXimum]
Parameter
<NRf>
0.01A/s~20.00A/s (PFR-100L50)
0.001A/s~4.000A/s (PFR-100M250)
MINimum
Minimum rising current slew rate.
MAXimum Maximum rising current slew rate.
Return
parameter
<NR2>
Returns the rising current slew rate in amps.
Example
:CURR:SLEW:RIS 20
Sets the rising current slew rate to 20A/ms.
Query
example 1
:CURR:SLEW:RIS?
>+5.000
Returns the rising current slew rate.
Query
example 2
:CURR:SLEW:RIS? MAX
>+20.000
Returns the maximum rising current slew rate.
4-10-8. [:SOURce]:CURRent:SLEWrate:FALLing
Set
Query
Description
Sets or queries the falling current slew rate. This is only
applicable for CC slew rate priority mode.
Syntax
[:SOURce]:CURRent:SLEWrate:FALLing {<NRf>|MINimum |
MAXimum}
Query Syntax [:SOURce]:CURRent:SLEWrate:FALLing? [MINimum |
MAXimum]