4-7-3. :OUTPut:MODE
Set
Query
Description
Sets the PFR-100 output mode. This is the equivalent to the F-03
(V-I Mode Slew Rate Select) settings.
Syntax
:OUTPut:MODE {<NR1> | CVHS | CCHS | CVLS | CCLS}
Query Syntax :OUTPut:MODE?
Parameter
0 / CVHS CV high speed priority
1 / CCHS CC high speed priority
2 / CVLS CV slew rate priority
3 / CCLS CCV slew rate priority
Return
parameter
<NR1>
Returns the output mode.
Example
:OUTP:MODE CVHS
Sets the output mode.
Query
example
:OUTP:MODE?
>0
Returns the output mode.
4-7-4. :OUTPut[:STATe][:IMMediate]
Set
Query
Description
Turns the output on or off.
Syntax
:OUTPut[:STATe][:IMMediate] {<Boolean> | OFF | ON}
Query Syntax :OUTPut[:STATe][:IMMediate]?
Parameter
0 / OFF
Turns the output off.
1 / ON
Turns the output on.
Return
parameter
<Boolean> Returns output status of the instrument.
Example
:OUTP ON
Sets output status of the instrument.
Query
example
:OUTP?
>1
Returns output status of the instrument.