43
Return
parameter
<Boolean>
0
The OVP has not been tripped.
1
The OVP has been tripped.
Query
example
:VOLT:PROT:TRIP?
>0
The OVP has not been tripped.
4-10-16. [:SOURce]:VOLTage:SLEWrate:RISing
Set
Query
Description
Sets or queries the rising voltage slew rate. This is only
applicable for CV slew rate priority mode.
Syntax
[:SOURce]:VOLTage:SLEWrate:RISing {<NRf> | MINimum |
MAXimum}
Query Syntax [:SOURce]:VOLTage:SLEWrate:RISing? [MINimum | MAXimum]
Parameter
<NRf>
0.1V~100.0V/s (PFR-100L50)
0.1V~500.0V/s (PFR-100M250)
MINimum
Minimum rising voltage slew rate.
MAXimum Maximum rising voltage slew rate.
Return
parameter
<NR2>
Returns the rising voltage slew rate in volts.
Example
:VOLT:SLEW:RIS MAX
Sets the rising voltgae slew rate to its maximum.
Query
example 1
:VOLT:SLEW:RIS?
>+10.000
Returns the rising voltage slew rate.
Query
example 2
:VOLT:SLEW:RIS? MAX
>+100.000
Returns the maximum rising voltage slew rate.
4-10-17. [:SOURce]:VOLTage:SLEWrate:FALLing
Set
Query
Description
Sets or queries the falling voltage slew rate. This is only
applicable for CV slew rate priority mode.
Syntax
[:SOURce]:VOLTage:SLEWrate:FALLing {<NRf>|MINimum |
MAXimum}
Query Syntax [:SOURce]:VOLTage:SLEWrate:FALLing? [MINimum |
MAXimum]
Parameter
<NRf>
0.1V~100.0V/s (PFR-100L50)
0.1V~500.0V/s (PFR-100M250)
MINimum
Minimum falling voltage slew rate.
MAXimum Maximum falling voltage slew rate.
Return
parameter
<NR2>
Returns the falling voltage slew rate in volts.
Example
:VOLT:SLEW:FALL MIN
Sets the falling voltgae slew rate to its minimum.