5-4. Operation Status Register Group
Overview The Operation Status Register Group indicates the operating status of
the power supply.
CAL
Not Used
Not Used
Not Used
Not Used
WTG
Not Used
Not Used
CV
Not Used
CC
OND
OFD
Not Used
PR
Not Used
PTR/NTR
Event
Enable
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Operation Status Register
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
Logical OR
To OPER in Status Byte Register
STATus:OPERation:CONDition?
STATus:OPERation:EVENt?
STATus:OPERation:NTRansition <NRf>
STATus:OPERation:NTRansition?
STATus:OPERation:PTRansition <NRf>
STATus:OPERation:PTRansition?
STATus:OPERation:ENABle <NRf>
STATus:OPERation:ENABle?
Condition
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Bit
Summary
Bit
name
Event
Bit #
Bit
Waight
CAL
Calibration mode
Indicates if the PFR-100 is in calibration mode.
0
1
WTG Waiting for trigger
Indicates if the PFR-100 is waiting for a trigger.
5
32
CV
Constant voltage mode
Indicates if the PFR-100 is in CV mode.
8
256
CC
Constant current mode
Indicates if the PFR-100 is in CC mode.
10
1024
OND Output ON Delay
Indicates if Output ON delay time is active
11
2048
OFD Output OFF Delay
Indicates if Output OFF delay time is active
12
4096
PR
Program Running
Indicates if a Test is running
13
8192
Condition
Register
The Operation Status Condition Register indicates the operating
status of the power supply. If a bit is set in the Condition register, it
indicates that the event is true. Reading the condition register does
not change the state of the condition register.