76
UART Parity
F-73
0 = None
UART Stop Bit
F-74
0 = 1bit
UART TCP
F-75
0 = SCPI
Power On Configuration
setting
Setting
Default Setting
CV Control
F-90
0 = Panel control (local)
CC Control
F-91
0 = Panel control (local)
Power ON Output
F-92
0 = Safe Mode (Output Off at startup)
External Output Logic Control F-94
0 = High ON
The contents of the Test Mode are not cleared at initialization of F-88.
Clear the Delete Test Data.
The contents of the memory data (M1, M2, M3) are not cleared for F-88
initialization.
The Interface Select (F-29) setting is not initialized in F-88.
The UART address (F-76) and the Multi-drop control (F-77) settings are not
initialized in F-88.
6-2. Error Messages and other Messages
The following error messages or other messages may appear on the PFR-100
screen during operation.
Error Message
Description
OHP
Over temperature protection
SENSE ALARM1
Sense Alarm1
SENSE ALARM2
Sense Alarm2
AC
AC fail
OVP
Over voltage protection
OCP
Over current protection
SHUTDOWN
Force shutdown
Err 001
USB mass storage is not present
Err 002
No (such) file in USB mass storage
Err 003
Empty memory location
Err 004
File access error
Err 005
File size error
Err 007
Slave occurs Off-line (Multi-Drop mode)
Normal Messages
Description
MSG 001
External control of output. Output off
(F-94 = 0, High = on)
MSG 002
External control of output. Output off
(F-94 = 1, Low = on)
Communication
Interface Messages
Description
MS ON
Mass storage plugged into front USB port
MS OFF
Mass storage removed from front USB port