V2.71 - Page 36 of 59
3.1.3.2
TGW-100 configuration
On the TGW-100, "TETRA
Cassidian gateway" must be configured according to the
installation of the TCS_Gateway application and the infrastructure settings:
TCS gateway IP: This is the IP address of your server running the TCS_Gateway
application
TCS gateway port: This is the port number of the TCS_Gateway instance which is
responsible for this TGW-100 (10000 in our example). Each TGW-100 needs a
unique instance and port number on the gateway server.
Two independent TCS gateway addresses can be configured: A primary TCS gateway
connection and a secondary TCS gateway connection. Below these settings, the use of
the primary or the secondary gateway connection can be selected. In addition to this, a
switchover time between 0 and 60 minutes can be configured for a redundancy
switching.
If the switchover time is configured, the TGW-100 will automatically switch to the
other TCS gateway address if the selected interface fails (i.e. if the SwMi is down). If
this setting is set to 0 minutes, no automatic switching will occur.
Please note that the TGW-100 will stay connected to the SwMi after the switching, it
will not automatically switch back to the previous used connection. If the TGW-100
should use again the old connection, it must be switched back manually. Of course, if
the second connection also fails, the TGW-100 will go back and try the first connection
after the switchover time has passed without a valid connection to the SwMi.