Funk-Electronic Piciorgros GmbH
TGW-100/TGW-100R
V2.71 - Page 11 of 59
2.2
TGW-100: DIN-Rail-Version
2.2.1
Mechanical Details
The dimensions of the TGW-100 housing conform to DIN 43880, and therefore it can
be mounted on a standard 35mm DIN rail [DIN EN 50022]. Two serial interfaces are
provided for connecting the TGW-100 to a PC/PLC or other local terminal equipment.
The main serial interface ("COM") uses a standard 9-pin D-sub connector, while the
secondary serial interface ("AUX") uses a standard RJ-11 socket. On the lower side of
the housing an RJ-45 connector for the Ethernet port allows the TGW-100 to be hard-
wire networked with the TETRA infrastructure.
On the left upper side of the unit is located the plug-in terminal connector for the power
supply (12-24 VDC +/-20%) and a BNC socket for the antenna.
A 10-pole DIP-switch allows quick changes to the unit's settings: e.g., changeover to
Programming Mode.
LED lamps on the front panel provide information about the operating condition of the
unit: e.g., received TETRA RF signal strength, error conditions, etc.
2.2.2
Dimensions
The dimensions of the TGW-100 are as follows:
162mm (9T) wide x 80mm high x 62mm deep
All dimensions exclude connectors.