Funk-Electronic Piciorgros GmbH
TGW-100/TGW-100R
V2.71 - Page 15 of 59
2.3.2
Secondary Serial Interface (AUX Interface) on TGW-100 DIN-Rail
On the TGW-100 DIN-Rail-version, the AUX interface socket is located on the lower
side of the unit. This interface allows the implementation of special applications, e.g.,
switching of the data-flow through this interface by a command, or feeding data from a
predefined ISSI to this port rather that to COM.
This secondary interface is provided through a 6-pin RJ-12 connector and equipped
default with an RS-232 interface. The unit can be ordered optional with an RS-485
interface (RS-422 is not possible on the AUX port).
Pin No.
Pin Assignment: Auxiliary Interface, RS-232
1
GPS Supply voltage
2
RTS
Handshake TGW-100
peripheral
3
RxD
Receive data TGW-100
peripheral
4
TxD
Send data TGW-100
peripheral
5
CTS
Handshake TGW-100
peripheral
6
GND
Pin No.
Pin Assignment: Auxiliary Interface, RS-485
1
GND
3
B
Transceiver –
4
A
Trans
6
GND
On the TGW-100R rack version, also the AUX port is realized with a standard