Specifications TGW-100R
Function:
Gateway for connecting serial based equipment directly to a
TETRA infrastructure for communication with TMO-100
outstations
Interfaces:
COM:
AUX:
Ethernet:
RS-232 or RS-485/422, DB9 (F)
RS-232 or RS-485, RJ12, DB9 (F)
Two 10/100 Mbit/s Ports
Operating modes:
SDS-based data communication (on supported infrastructures)
Packet data based communication
Protocols:
MODBUS-RTU, ROC
IEC-60870-5-101
DNP3, PakBus, BSAP
Custom protocols
Indicators:
Front panel LED indication for all interfaces and connection
status to the TETRA infrastructure
EMC Conformance
EN 301 489-1 und -18
ESD Conformance
61000-4-2 von 1998
Power supply voltage:
90 – 240V AC, 50-60Hz
Enclosure:
Cassette for mounting in 19” Rack
Enclosure Width:
19”
Operating Temperature: