Funk-Electronic Piciorgros GmbH
TGW-100/TGW-100R
V2.71 - Page 22 of 59
2.5
Reset to factory default (DIN-Rail version)
The TGW-100 can be reset to the factory default configuration. Also the Ethernet
parameter can be reset independently, if the IP address is not known any more.
2.5.1
General Reset of the Device to Factory Default
Using the following procedure, the TGW will be reset to factory default. All parameter
will be cleared, the IP address will be set to 192.168.0.199.
Disconnect the device from power supply
Set DIP-switch 10,9,6,5 and 1 to "on" all other to “off”
Apply power to the device
If the LED’s in the RF-display Stepp from left to right (single LED), set DIP 10
to „off“
Now two pairs of 4 LED each flash indicating that the unit is resetting. Now wait
until the device reset is ready, and the unit will restart again.
After the restart, all DIP-switches should be reset to „off“