The following example will explain what happens on the receiver side, if the following
#-commands will be sent to a TGW-100 with an ISSI=4711 that is configured for #-
command mode:
Example 1:
#T12345#This is a test message
Will be stored as an SDS in a Tetra Terminal with the ISSI (GSSI) 12345 as:
This is a test message
Will be sent out on the TGW-100s (ISSI: 12345) serial port that is configured for #-
commands as:
#T4711# This is a test message
Remark: 4711 is the sender ISSI
Example 2:
#S12345#52000
Will be sent as a status message to a Tetra Terminal with the ISSI (GSSI) 12345
Will be sent out on the TGW-100s (ISSI: 12345) serial port that is configured for #-
commands as:
#S4711# 52000
Remark: 4711 is the sender ISSI
Example 3:
#D12345# This is a test message
Can not be displayed correctly on a Tetra Terminal with the ISSI (GSSI) 12345
Will be sent out on the TGW-100s (ISSI: 12345) serial port that is configured as
slave
as:
This is a test message
Remark: No sender ISSI will be included in the output