Funk-Electronic Piciorgros GmbH
TGW-100/TGW-100R
V2.71 - Page 31 of 59
3.1.2
SDS services for Etelm infrastructures
In TETRA
Etelm Gateway all needed parameters can be configured:
ISSI: The ISSI of the TGW-100. SDS data from the outstations needs to be sent to
this ISSI to be received by the TGW-100. Each TGW-100 needs a different,
unique ISSI. This will be provided by the network operator.
IP address: IP address of the Etelm infrastructure. This will be provided by the
network operator.
SDS-Server TCP and UDP ports: The ports which are configured for the
dispatcher connection of the infrastructure. Normally both port numbers are the
same. These will be provided by the network operator.
As soon as all parameters are configured, the TGW-100 will indicate a needed restart.
After the reboot, the TGW-100 will start to connect to the infrastructure. As soon as the
connection is established, all RF LED's will be lit (on the TGW-100 DIN-Rail version)
and the blue LED (named "PPP" on the TGW-100 DIN-RAIL, and "Link" on the TGW-
100R rack version) will be lit. This blue LED will indicate a proper connection between
TGW-100 and TETRA infrastructure.