Funk-Electronic Piciorgros GmbH
TGW-100/TGW-100R
V2.71 - Page 52 of 59
5
Configuring the TGW-100
5.1
Configuring the TGW-100 through the Integrated Web Server
The adjustable parameters of the TGW-100 can be configured through the integrated
Web server from a conventional browser. This can be done over its Ethernet interface.
The Web server responds to queries through Port 80.
Example:
The TGW-100 is delivered with a factory-installed IP address 192.168.0.199 for the
Ethernet interface. A PC connected to this interface has the (for example) the IP address
192.168.0.26. To configure the TGW-100, type http//192.168.0.199 in the address
window of the browser and hit "Enter". If necessary, a fixed IP address in the range
192.168.0.xxx may need to be assigned to the connected PC.
The TGW-100 can be connected using a 1:1 patch cable if connecting to the PC via a
switch or hub. If connecting to a PC directly, use a crossed cable.
The TGW-100 will respond with a login window.
The default login is "user" / "user".