background image

Funk-Electronic Piciorgros GmbH 

TGW-100/TGW-100R

 

V2.71 - Page 19  of   59 

2.4.2

 

DIN-Rail version 

Summary of Contents for TGW-100

Page 1: ...TGW 100R TGW 100 TETRA Gateway for Packet Data and SDS Applications V 2 71 June 2013 www 2test ru 7 495 215 57 17 info 2test ru...

Page 2: ...ED Blink Pattern Error Indication 21 2 5 Reset to factory default DIN Rail version 22 2 5 1 General Reset of the Device to Factory Default 22 2 5 2 Resetting the Ethernet Parameter 23 2 6 Configuratio...

Page 3: ...ut Protocol Filter User Defined 51 4 2 9 Hart Protocol 51 5 CONFIGURING THE TGW 100 52 5 1 Configuring the TGW 100 through the Integrated Web Server 52 6 MAITENANCE 53 6 1 TGW 100 Firmware update proc...

Page 4: ...r prior written permission 1 3 Disclaimer We have carefully checked the contents of this document and the hardware and software described in it for compatibility We cannot however exclude possibilitie...

Page 5: ...s IP based protocols can directly be connected to the TETRA switch serial based protocols must use a gateway device for being connected to the infrastructure featuring also a protocol address detectio...

Page 6: ...ta transmission is done by packet data IP based in the TETRA network For a SDS based data transmission the protocol to send and receive SDS and Status messages is proprietary for each infrastructure m...

Page 7: ...n Comments Changes 2 20 2 20 Documentation Release 2 60 2 60 TGW 100 supports SDS gateway mode for Cassidian infrastructures TCS server needed Support of TGW 100R rack mount version 2 70 2 70 TGW 100...

Page 8: ...driver software is needed to interface the TGW 100R to the different TETRA infrastructure manufacturers 2 1 2 Mode of operation Each of the serial ports can be configured independent for a protocol s...

Page 9: ...2 1 4 Interfaces Both serial interfaces COM and AUX use a standard 9 pin D sub connector Also available on the front panel are two Ethernet connectors which are connected by an internal Ethernet swit...

Page 10: ...you may ask for cables fitting the needs Also standard cables with IEC plug may be used but please aware that you ll lose the removal lock with a standard plug IEC plug with removal lock As each powe...

Page 11: ...J 11 socket On the lower side of the housing an RJ 45 connector for the Ethernet port allows the TGW 100 to be hard wire networked with the TETRA infrastructure On the left upper side of the unit is l...

Page 12: ...e tilted downward slightly The Module is then pushed upward 1 and rotated backward 2 until the upper lip of the clip snaps onto the upper flange of the DIN rail 2 2 4 Dismounting To dismount the Modul...

Page 13: ...12 24 VDC 20 is connected through 3 way screw terminal connector located on the upper side of the enclosure The terminals are assigned as follows viewed from the front of the module facing the front...

Page 14: ...faces are supplied as RS 232 unless ordered otherwise The primary interface is optionally available as a user selectable RS 485 RS 422 port while the AUX interface is optionally available as an RS 485...

Page 15: ...that to COM This secondary interface is provided through a 6 pin RJ 12 connector and equipped default with an RS 232 interface The unit can be ordered optional with an RS 485 interface RS 422 is not p...

Page 16: ...an Ethernet network is connected LINK Yellow LED Blinks when data transfer is taking place DATA Network parameters such as IP address netmask and gateway address can be assigned as a static address A...

Page 17: ...7 of 59 2 4 LED Functions Groups of LED lamps on the front panel of the TGW 100 indicate the operating condition of the modem the link to the TETRA infrastructure and error conditions if any Specific...

Page 18: ...x Lights up while the TGW 100 receives data via the AUX interface IP Tx Lights up while the TGW 100 sends data to the infrastructure for packet data transmission IP Rx Lights up while the TGW 100 rece...

Page 19: ...Funk Electronic Piciorgros GmbH TGW 100 TGW 100R V2 71 Page 19 of 59 2 4 2 DIN Rail version...

Page 20: ...ts up while SDS or Status data is being sent to the infrastructure Radio Rx Lights up while SDS or Status data is being received from the infrastructure RF These Led bar indicates the correct registra...

Page 21: ...the proper device operation If this LED is flashing or off it indicates an exception Different blinking codes can indicate different problems as shown in the table below Blink Pattern Meaning LED off...

Page 22: ...lowing procedure the TGW will be reset to factory default All parameter will be cleared the IP address will be set to 192 168 0 199 Disconnect the device from power supply Set DIP switch 10 9 6 5 and...

Page 23: ...199 subnet mask 255 255 255 0 All other parameter will be unaltered Disconnect the device from power supply Set all DIP switches to on Apply power to the device If the LED s in the RF display steps fr...

Page 24: ...TGW The following screen will then be displayed The login will be done using the default username and password take care as both are case sensitive Username user Password user These passwords can be c...

Page 25: ...nic Piciorgros GmbH TGW 100 TGW 100R V2 71 Page 25 of 59 2 6 1 Navigation using the Menu To select a menu move the cursor over the desired headword and click it Then the menu will open displaying the...

Page 26: ...changes change of Ethernet or Tetra parameter need a restart of the device before they will take effect If these changes have been done by the user an orange button with the text Restart Device is dis...

Page 27: ...going up to full 1460 bytes in networks which supports the full specified length of 254 bytes per SDS The packets are broken down if necessary transparent to the user into smaller SDS data blocks Ser...

Page 28: ...n the TETRA network is possible with all infrastructures which allow the connection of IP based devices to the TETRA switch for communication with TETRA radio modems using packet data In contrast to S...

Page 29: ...00 at either end and makes the TGW 100 compatible even with older TETRA networks In this respect radio data communication through TGW 100 modems behaves like wire communication with minimum transmissi...

Page 30: ...for the use of SDS based transmission This selection is done in TETRA Gateway selection Some infrastructure manufacturers may be subject to a license for the TGW 100 so not all options may be availab...

Page 31: ...e network operator SDS Server TCP and UDP ports The ports which are configured for the dispatcher connection of the infrastructure Normally both port numbers are the same These will be provided by the...

Page 32: ...eway which does not need an installation on the PC Also this application can be started in multiple instances on a single PC so that the PC can handle the connection of several TGW 100 to the Cassidia...

Page 33: ...mbH TGW 100 TGW 100R V2 71 Page 33 of 59 To specify the IP port you need to create a link in the same directory Make a right click on the TCS_Gateway exe and select Create Link You will get the link c...

Page 34: ...TGW 100R V2 71 Page 34 of 59 Right Click on the link and select Properties In the Target line add the port number behind the TCS_Gateway exe We ll use 10000 in this example Click OK If you like you ca...

Page 35: ...ot start the exe file itself as in this case it will not listen on a port for incoming connections from a TGW 100 Use always different port numbers for each instance of the TCS_Gateway application Don...

Page 36: ...onnection Below these settings the use of the primary or the secondary gateway connection can be selected In addition to this a switchover time between 0 and 60 minutes can be configured for a redunda...

Page 37: ...Password Password for the username above DCOM IP name If a COM connection common in most installations is used for the TCS server connection leave this field blank If DCOM is used you need to specify...

Page 38: ...use of the primary or the secondary ACAPI connection can be selected In addition to this a switchover time between 0 and 60 minutes can be configured for a redundancy switching If the switchover time...

Page 39: ...Funk Electronic Piciorgros GmbH TGW 100 TGW 100R V2 71 Page 39 of 59 To select the use of the Hytera ACAPI gateway if must be selected on the page TETRA Gateway Selection...

Page 40: ...re also user programmable Protocol Configuration When a data block is received at the serial interface of the TGW 100 it waits for the complete data block to be received The data block end criterion i...

Page 41: ...eive the same data Each terminal equipment connected to the slave modems is then responsible for determining whether a data block is intended for it or not It should be noted that when SDS is broadcas...

Page 42: ...aster modem can be set in the slave modem so that all data received from local terminal equipment is sent only to this ISSI 3 1 6 1 Routing SDS Data to the Primary COM or Secondary AUX Interface The T...

Page 43: ...is decompressed before moving it out Data compression can improve performance when large data blocks are involved by reducing the data that is conveyed over the TETRA network even if additional SDS b...

Page 44: ...SI Text Data or Status Control character ISSI GSSI Text or Status Remark T Yes Text Sends a Text SDS S Yes Numeric Status 0 65535 Sends a Status Message D Yes Text or Data Sends Text or Data including...

Page 45: ...5 serial port that is configured for commands as T4711 This is a test message Remark 4711 is the sender ISSI Example 2 S12345 52000 Will be sent as a status message to a Tetra Terminal with the ISSI G...

Page 46: ...ive PD connection over which data is to be transferred affects the availability of the voice channels this must be taken into account at the time of network planning Also the TETRA radios are not addr...

Page 47: ...he Ethernet IP of the TGW 100 must allow the communication with the data router IP gateway of the TETRA network Therefore the TGW 100 must be in the same subnet than the IP gateway of the TETRA infras...

Page 48: ...Factory default is set to 10 ms for 9600 bps That reflects 10 characters in sequence Basically if used other baud rates a timeout period of 10 character times is suggested Using the COM interface a t...

Page 49: ...W extracts this logical address byte and using the predefined address translation or routing table it can convert the protocol address into the destination ISSI of the Tetra target device Using that t...

Page 50: ...master device unsolicited messaging Serial DNP3 was tested with the TGW 100 simultaneously with the HART protocol The DNP3 was communicating over the COM port while HART was transferred via AUX In tha...

Page 51: ...transmitted using the Group ISSI or a fixed prede fined ISSI Care should be taken when using the GISSI communication as this method increases the over all load of Tetra networks In case the ISSI param...

Page 52: ...delivered with a factory installed IP address 192 168 0 199 for the Ethernet interface A PC connected to this interface has the for example the IP address 192 168 0 26 To configure the TGW 100 type h...

Page 53: ...KIN software Firmware files for the TGW 100 6 1 2 Update procedure For the update two firmware files are needed The file with the extension pfw is the firmware file the one with the extension pch is t...

Page 54: ...t Execute and then type cmd Change to the directory where you ve put the firmware files Transfer the pfw file to the device using the command tftp i 192 168 0 199 PUT filename pfw The IP here is the d...

Page 55: ...cess has finished the TGW will not show any action on it s LED for about 15 20 seconds then it will restart After the TGW has restarted and is alive the power can be disconnected The pch file must alw...

Page 56: ...o must remain untouched must be transferred to the TGW 100 The complete configuration will be changed according the saved one however the device properties as serial number and enabled features will r...

Page 57: ...10 100 Mbit s Ports Operating modes SDS based data communication on supported infrastructures Packet data based communication Protocols MODBUS RTU ROC IEC 60870 5 101 DNP3 PakBus BSAP Custom protocols...

Page 58: ...on 19 Rack for TGW 100R with redundant power supply Power Supply Input Power Range Two separate mains connector plugs 90 240 VAC Indicators Front panel LED indication Power Output Voltage 24 VDC 20 12...

Page 59: ...ed communication Protocols MODBUS RTU ROC IEC 60870 5 101 DNP3 PakBus BSAP Custom protocols Indicators Front panel LED indication for all interfaces and connection status to the TETRA infrastructure E...

Reviews: