7 Standard Operating Procedures
Operations Manual
Bison 120
20-07-2018
Page 7-14
Revision 2.0
Figure 7.12 - Chamber Start Button
5. If fitted with optional magnetic belt, press the start button (Item 1), Reference: Figure 7.13.
This will start the magnetic belt.
Figure 7.13 - Chamber Start Button
6. On the radio remote press the vibrating drawer start button (Item 1). This will start the vibrating
drawer. The speed of which the drawer feeds the material to the chamber can be regulated
using the speed regulator (Item 2), Reference: Figure 7.14.
Figure 7.14 - Vibrating Drawer Button
7. The vibrating drawer speed can also be regulated by altering the positions of the weights on
the vibrating motors, see maintenance section.