Troubleshooting 10
Operations Manual
Bison 120
20-07-2018
Page 10-7
Revision 2.0
(6) Production
Fault
Cause
Correct Measure
Low Product Output
Not enough raw material
delivered to machine
Increase feed rate.
Not enough hauling equipment
for finished product
Increase removal rate.
Incorrect machine parameter
settings
Change parameter settings
Incorrect or worn liners
Replace liners
Incorrect mesh fitted
Replace mesh
Product out of
specification
Incorrect or worn liners
Replace liners
Incorrect mesh fitted
Replace mesh
Incorrect machine parameter
settings
Change parameter settings
(7) Tracks
Fault
Cause
Correct Measure
Excessive oil
leaking around drive
assembly
Seal damaged between Motion
control block and motor
Remove motion control block and
replace seals
Seal damaged between motor
and gearbox
Remove motor and replace seal
Seal damage may be caused by
excessive oil temperatures
Check oil operating temperature
and environmental conditions
Track will not stay
tensioned
Grease escaping
Check that the track adjuster
grease valve is tight, has a
properly fitted seal and that there
is no grease leaking past it
Check around the tensioning
Cylinder for escaping grease.
This will indicate that the seals
are damaged in the tensioning
cylinder. Replace with a new
cylinder immediately
Track roller leaking oil Damaged or worn seals
Replace with a new Track Roller
Summary of Contents for Evoquip Bison 120
Page 2: ...EvoQuip 200 Coalisland Road Dungannon Co Tyrone BT71 4DR Telephone 44 0 28 8774 0701...
Page 208: ...Appendix A Operations Manual Bison 120 20 07 2018 Page A 2 Revision 2 0...
Page 219: ...Appendix C Operations Manual Bison 120 20 07 2018 Page C 5 Revision 2 0 c Main Wiring...
Page 220: ...Appendix C Operations Manual Bison 120 20 07 2018 Page C 6 Revision 2 0 d Relay Box...
Page 223: ......