Troubleshooting 10
Operations Manual
Bison 120
20-07-2018
Page 10-17
Revision 2.0
Problem
Possible Cause
Procedure
Intermittent engine
shutdown
Emergency stop switches
Check that all emergency stops
are depressed and functioning
correctly
Electrical connections
Check and clean electrical
connections between the engine
ECM system display
Circuit breakers
Check the status of circuit
breakers
Fuel supply
Check the fuel level, do not rely
on the fuel gauge only, add fuel
as necessary
Check the fuel lines for
restrictions, collapsed and
pinched lines, have the engine
manufacturer repair and replace
as necessary
Check fuel in the tank for
contamination
Check condition of fuel filters,
replace as necessary
Diagnostic code
Check the display for fault code
and refer to engine manual for
instructions