TSP Edge User’s Manual
40-400-00065, Rev. E
114
Problem:
Error message “Port Already Open”
Another device is using the selected serial port. This could be another Edge
unit, or another application.
Solution:
1. Select a different serial port to connect to this unit.
2. Close other application that is using this serial port.
Icon:
Problem:
Error message ”Installed card types do not match defined card types”
Solution:
1. Power down the Edge and place cards into same card slots as defined in
the current project.
2. Redefine the card types in the Unit edit screen. To do this, all channels
within the unit would need to be removed from control sets.
Icon:
Problem:
Error message “Unit ‘name’ requires a License Code to enable its operation.
Contact Teltone Corporation
Solution:
All Edge units require a license code to enable their operation. Contact Teltone
customer service to obtain a license code for your unit.