background image

TSP Edge User’s Manual

 

 

 

40-400-00065, Rev. E 

114

Problem: 

Error message “Port Already Open” 

Another device is using the selected serial port. This could be another Edge 
unit, or another application.

 

Solution: 

1. Select a different serial port to connect to this unit. 

2.  Close other application that is using this serial port. 

 

Icon: 

 

Problem: 

Error message ”Installed card types do not match defined card types”

 

Solution: 

1.  Power down the Edge and place cards into same card slots as defined in 

the current project. 

2.  Redefine the card types in the Unit edit screen. To do this, all channels 

within the unit would need to be removed from control sets. 

 

Icon: 

 

Problem: 

Error message “Unit ‘name’ requires a License Code to enable its operation. 
Contact Teltone Corporation

 

Solution: 

All Edge units require a license code to enable their operation. Contact Teltone 
customer service to obtain a license code for your unit. 

 

Summary of Contents for TSP Edge

Page 1: ...TSP Edge User s Manual 40 400 00065 Rev E ...

Page 2: ...ed Trademarks Teltone is a registered trademark of Teltone Corporation TSP is a trademark of Teltone Corporation Windows is a registered trademark of Microsoft Corporation Other company and product names may be trademarks or registered trademarks of their respective owners Teltone Corporation Bothell Washington USA Customer Service 425 951 3388 Technical Support 425 951 3390 Fax 425 487 2288 Email...

Page 3: ...uirements 9 Power 9 PC 10 Checking Your Edge Package 10 Optional Hardware 10 Optional Software Modules 11 Installing Hardware Modules 11 Communications Connections 12 Console Port 13 10 100 LAN Ethernet Connection 13 Powering Up the Edge 13 Installing Edge Software 14 Programming the Edge 14 Basics 14 Main Window 15 Menus 15 Tree Display 16 Information Section 16 Icons 16 Control Set Enables 17 Un...

Page 4: ...on 51 Event Log 52 Diagnostics 55 Trace 56 Test Automation Interface 58 Basic Operation 58 Communicating with Edge Configuration Software Using DDE 59 Communicating with Edge Configuration Software Using TCP 60 Commands 61 GETMESSAGES 61 GETSTATUS 62 INITIALIZE 63 LISTCARDS 64 LISTCHANNELS 65 LISTFILES 66 LISTTASKS 67 LISTUNITS 68 LOADFILE 69 RUNTASK 70 SETDIAGNOSTIC 71 SETMONITOR 72 SETPRIEVENTS ...

Page 5: ...s 101 Line States 103 Tones Audio 105 Establishing Audio Connections between Channels 109 Assigning a Script to a Control Set 110 Sample Scripts 111 Troubleshooting 112 Warranty and Service 117 Warranty Information 117 Return Procedures 117 Technical Assistance 117 Maintenance 117 Cleaning 117 Servicing 117 Ordering Information 118 Hardware Chassis 118 Optional Hardware Modules 118 Optional Softwa...

Page 6: ...40 400 00065 Rev E vi 10 100 LAN Network PORT 153 T1 E1 Ports 153 POTS Ports 154 References 156 Glossary 158 Index 165 ...

Page 7: ...Type 29 Figure 20 Channel Identification 30 Figure 21 Channel Configuration Wizard 32 Figure 22 Template Type Tab 34 Figure 23 Template Timings Tab 37 Figure 24 Template Signaling Tab 38 Figure 25 Control Set 40 Figure 26 Channel Assignments Analog 43 Figure 27 Channel Assignments T1 Channels 44 Figure 28 End to End Control Set Example 46 Figure 29 Connecting Channels 46 Figure 30 Alerts Tab 48 Fi...

Page 8: ...og Box with a Script Assigned 110 Figure 50 Console Port Pin out 152 Figure 51 Serial Cable RJ11 to RJ11 152 Figure 52 Serial Cable Adapters 152 Figure 53 Network Port Pin out 153 Figure 54 Ethernet Cross Over Cable 153 Figure 55 T1 E1 Module Pin out 153 Figure 56 T1 E1 Cable 154 Figure 57 8 Channel POTS FXO Module Pin out 154 Figure 58 POTS FXS Module Pin out 154 Figure 59 POTS Y Cable 155 ...

Page 9: ... Opening or removing covers may expose you to dangerous voltages or other risks Incorrect reassembly can cause electric shock when the appliance is subsequently used 5 If the product does not operate normally by following the operating instructions or if the product has been dropped or the cabinet has been damaged or if the product exhibits a distinct change in performance refer servicing to quali...

Page 10: ...gistration number The Industry Canada label or the abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment Industry Canada does not guarantee the equipment will operate to the user s satisfaction Before...

Page 11: ...are plug in modules Upgradeable software and hardware modular design Analog POTS and T1 E1 simulation in the same system Operates under Windows 95 98 2000 XP or Windows NT Programming and control can be done with either the serial or Ethernet connection Status display provides current state for each channel on off hook ringing etc Supports three call types o Originate calls placed by the Edge to a...

Page 12: ...h o Ringback Enable Duration Bulk call generation Diagnostics with ability to place channels in different signaling states and shows the signaling bit states on T1 E1 Trace for detailed call progress of a channel Ability to control multiple Edge units with a single computer via the Ethernet connection Typical Applications The Edge is configurable for three basic types of calls End to End Call Orig...

Page 13: ...her T1 E1 Clear Channel via the Control Set Dialed Channel Bank DS0 to DS0 for Clear Channel operation only and Switch Emulation are the types of End to End Control Sets used by the Edge The Edge cross connects a channel on the T1 E1 to another channel on the same T1 E1 see Figure 2 TSP Edge Equipment under Test Single or Dual T1 E1 Module T1 E1 Figure 2 Single T1 E1 End to End The Edge cross conn...

Page 14: ... under test in Call Originate mode Call Terminate mode is where the Edge receives calls from the equipment under test In both cases the Edge will count the calls and display the calls as completed unanswered or busy in the event log Once the calls are established a WAV file can be programmed to play to indicate that a call has taken place With Call Originate mode the Edge generates calls on the ch...

Page 15: ... some audio file playback when the external device answers This can be used to stress test the equipment under test Installation Tests The Edge can emulate the PSTN and be terminated to a PBX via a T1 E1 circuit or multiple POTS connections This allows for testing PBX programming and functionality before live traffic is cut over to it Telephony Interfaces The Edge has a modular design see Figure 7...

Page 16: ...dule see Figure 8 supports T1 E1 and PRI configurations Figure 8 Dual T1 E1 Module LINK This LED indicator shows that the T1 E1 link is active ERR This LED indicator shows that an error has occurred Single T1 E1 Module Discontinued The Single T1 E1 module is identical to the Dual T1 E1 except there is only one port ...

Page 17: ...d off hook conditions and DTMF signaling from the connected equipment The interface uses industry standard RJ11 jacks wired to RJ14 standards Figure 9 8 Channel POTS FXS Module 8 Channel POTS FXO Module The 8 Channel POTS FXO interface module see Figure 10 provides eight 8 channels which appear as telephones to the equipment under test The interfaces can detect ringing go on and off hook and trans...

Page 18: ...ailable per port Advanced Software Modules TSP PRI TSP PRI Primary Rate ISDN This software module includes the standard Edge features plus it adds either T1 or E1 Primary Rate ISDN to an Edge unit that has no PRI capability licensed T1 Primary Rate ISDN Includes multiple switch types o US National ISDN 2 o AT T 4ESS o AT T 5ESS o NT DMS 100 250 Simulates CPE end or Network end Provides the followi...

Page 19: ...TMF during a call Detect DTMF during a call Send test tones Detect broadband energy Detect voice Play multiple wave files on a channel License Codes Edge license codes are used for Enabling additional purchased software modules Setting warranty information For information about upgrading the Edge see Upgrades Tab on page 48 SETUP System Requirements Power Caution AC operating power must be within ...

Page 20: ...erating system 4 Mb required on the disk the application is installed on 7 Mb additional required to install the Adobe Acrobat reader Checking Your Edge Package When you receive your Edge unit you should receive the following components TSP EDGE 01 unit 120 VAC power cord RJ45 Ethernet cross over cable gray cable labeled RJ11 serial cable RJ11 to DB9 adapter RJ11 to DB25 adapter Two RJ45 T1 E1 cab...

Page 21: ... static shield packaging Installing Hardware Modules Before applying power to the Edge ensure that the telephony interface modules are installed per the following information and Table 1 Ensure the modules are securely seated and the thumb screws are tightened Note Slot count is 1 4 from left to right when looking at the back of the Edge 1 If using a T1 E1 module install it in slot 4 a Two T1 E1 m...

Page 22: ...OTS module must be installed to the left of any other module If using Single T1 E1 modules A Single T1 E1 module may be used in place of the Dual T1 E1 module in any of the above configurations Two Single T1 E1 modules may be used if no other modules are installed in the Edge The modules must be placed in slots 3 and 4 If using 4 Port POTS modules A 4 Port POTS module may be used in place of an 8 ...

Page 23: ...ernet Connections on the Edge Back Panel 10 100 LAN Ethernet Connection The network connection is a 10 100 Base T which can be used for configuration and control of the Edge and which is necessary for downloading voice messages and software upgrades to the Edge An Ethernet cross over cable RJ45 at both ends is provided for connecting directly to a PC If connecting via a network hub a standard stra...

Page 24: ...hod is to insert the CD ROM then select START RUN BROWSE then choose your CD ROM drive and the file labeled SETUP EXE Follow the on screen instructions For information about the current and previous versions of the software see Revision History on page 119 PROGRAMMING THE EDGE The Edge configuration software installed on the PC controls the Edge unit and its configuration Multiple projects can be ...

Page 25: ...it is powered up start the Edge configuration software The main window starts with a default project file and is ready for configuring the Edge see Figure 12 Figure 12 Configuration Software New Project Menus File for creating opening and saving project files and exiting the program View to access and clear the event log and to access Options Units to edit unit specific parameters for each Edge un...

Page 26: ...display tree and clicking the minus sign does the opposite See Figure 13 Figure 13 Main Window Information Section To the right side of the tree display is the information section The information section displays parameters and current states of the item chosen in the tree display Icons The following icons are used in the tree display and information section General Status Everything is OK Green D...

Page 27: ...eters for the connected device are configured the same as the unit Channel Status Channel is ringing No status available Channel is On hook Channel is Off hook Clear Channel Control Set Status Control set is running Control set Disable Control Set Finished Control Set Waiting for Start Time Control Set Enables The Control Set Enable buttons appear on the far right side of the main window once Cont...

Page 28: ...tion for the Ports and Channels on each card By clicking New on the Units menu the prompt Enter New Unit Name appears For demonstration purposes the name Unit Example is used in this manual After entering the name for your unit the Unit screen is displayed see Figure 14 with the unit name in the title bar Figure 14 Unit Screen Note the tabs on the Unit screen General Connection for Serial or Netwo...

Page 29: ...by clicking the Query Card Types button at the bottom of the Unit screen A message is displayed stating This will set the current units card types to match those actually in the system Click OK to continue The Unit screen s slot information now reflects the physical modules in the unit Teltone recommends using the Query Card Types button for configuring the Edge But if the unit is not connected to...

Page 30: ...ish to download to your unit now Note You must have a network connection to the unit to download The Edge must have an Ethernet connection and an IP address assigned for the download to be successful Click No if this has not been done and follow the instructions in the next subsection Once the Edge is assigned an IP address download the newer version to the unit by clicking OK on the Unit screen o...

Page 31: ...irectly using the crossover cable provided If connecting to a LAN contact your network administrator to assign a static IP for the unit To enter the IP address go to the Units menu click the unit name and select the Network tab on the Unit screen Use a valid IP format that is in the same subnet and uses a valid subnet mask Click OK Network Control A network connection can be used for controlling t...

Page 32: ...case the controlling PC loses its network connection It also facilitates controlling the unit from different locations To take control back when a connection is overridden go to the Units menu choose Initialize and the name of the unit Changing an IP Address To change the IP address of a unit go to the Units menu and select the unit The Unit screen is displayed Choose the Network tab enter the new...

Page 33: ...P address to the unit and select Network connection Module Configuration Slot Tabs Once the card types and the connection to the Edge are defined there are many different options to configure for each card type Choose each Slot tab that has a module installed and configure it according to the following subsections Single T1 E1 and Dual T1 E1 Card Types For T1 E1 modules the Card Mode field is disp...

Page 34: ...s as the PSTN and provides the clocking to the equipment under test External Clock is used when the Edge acts as the CPE and clocks from the equipment under test i e if the Edge is set for Internal clock the equipment under test should be set for External clock and vice versa Note If using only one port on a Dual T1 E1 that is configured for External Clock port 2 must be used and will derive its c...

Page 35: ...ard used in North America and Japan For E1 a law is the default and is the PCM encoding and companding standard used in Europe Important On Dual T1 E1 modules both ports are configured for the same clock framing and line coding Ensure the parameters are consistent with the configuration of the equipment under test This information can be found in the equipment manual or by contacting the vendor Li...

Page 36: ...lso if a Dual E1 module and a POTS module are used the last 8 channels for 4 Channel POTS or the last 12 channels for 8 Channel POTS are unavailable on the second E1 Clock The Clock needs to be set to where one end is providing timing normally the PSTN while the other end is deriving clock from it usually the CPE The Internal clock setting is used when the Edge acts as the PSTN and provides the cl...

Page 37: ...tream due to too many successive zeros PCM Encoding For PCM Encoding the choices are mu law and a law For T1 mu law is the default This is the PCM encoding and companding standard used in North America and Japan For E1 a law is the default and is the PCM encoding and companding standard used in Europe Important On Dual T1 E1 modules both channels are configured for the same clock signaling and lin...

Page 38: ... only a Channels tab is displayed see Figure 18 Figure 18 POTS FXS Card Type The 4 Channel POTS and 8 Channel POTS FXS Card Type screens are identical The only difference is the number of channels available to configure These channels operate as Analog Loop Start FXS only For information about the Channels tab see Channels Tab on page 29 ...

Page 39: ...ach channel can be assigned a Phone Number Transmit Digits T1 E1 only and Audio Message The Channel Configuration field assigns the channel an identification number see Channel Identification on page 30 The Subaddress Calling Number and Called Number fields are only available for T1 PRI and E1 PRI card modes For more information see Primary Rate ISDN Software Modules TSP PRI and TSP 2PRI on page 8...

Page 40: ...module The 01 is for the first channel of two on each port of the 8 Channel POTS module Note that the breakdown for the channel assignment is displayed just beneath the Channel Configuration box on the POTS screen All the parameters available for the T1 E1 cards under the Channel Configuration are identical on the 4 and 8 Channel POTS Card Type screens except for Transmit Digits which is only avai...

Page 41: ...ble it otherwise the message is played only once Audio Messages must be created and stored in mu law or a law encoded 8 bit Wave file format and are stored in the PC in the Audio folder The Edge automatically converts a Wave file between a law and mu law in order to transmit them in accordance with the unit s port configuration Messages that are less than 8 seconds in length with a total combined ...

Page 42: ...sing the value in the Starting Number field modified in one of two ways The Slot Port Channel option assigns the last four digits according to the channel s location in the Edge Selecting the Increment option enables the Increment field Each channel is given the Starting Number plus the Increment used i e Starting Number 12345678901 for Increment of 3 Channel 1 12345678901 channel 2 12345678904 ch...

Page 43: ...will be simulating 3 Configure the Channels tab for all the installed modules Each channel can be assigned a Phone Number T1 E1 and POTS Transmit Digits i e ANI and DNIS for T1 and E1 and Audio Message the network connection must be established For T1 PRI and E1 PRI Subaddress Called Number and Calling Number features are also available For more information see Channels Tab on page 29 The Channel ...

Page 44: ... Protocol arrow to choose an option scroll down to see all options Once a template is assigned to a control set the channel type cannot be changed for more information see Control Sets on page 40 Table 2 Channel Protocols ANALOG PROTOCOLS Analog Loop Start FXS This is used only with 4 or 8 Channel POTS FXS modules The channel provides battery ground and ringing to the terminating set Analog Loop S...

Page 45: ...E1 The signaling bits use Delay Dial protocol T1 E1 Wink Start This is used when the Edge interfaces with the equipment under test as an Wink Start circuit on the channel of the T1 E1 The signaling bits use Wink Start protocol T1 E1 Clear Channel This is used when the Edge interfaces with the equipment under test to cross connect two T1 E1 channels to provide for clear channel operation The T1 sho...

Page 46: ...channel You can disable Ringback by clearing the Ringback check box Hook Flash Detect This option allows detection of hook flash to perform transfers It only allows transfers between analog FXS lines in a dialed control set Trunk Type This option gives the choice of Tie Trunk or CAMA for T1 E1 Wink Start Delay Dial and Immediate Dial Tie Trunk is for end to end signaling CAMA operation is where a ...

Page 47: ...imal point If you click to the right of the decimal point the arrows change the numbers to the right of the decimal point You may also enter the value directly using the keyboard The DTMF Transmit Length may be set between 50 and 200 milliseconds in 12 5 millisecond increments All other values may be set from 0 to 300 seconds in 5 millisecond increments All timings are reset to default settings by...

Page 48: ...ed protocol and has Factory Default listed This uses the bits states as defined by the standard for the Channel Protocol chosen on the Type tab Clicking the arrow lists equipment that Teltone Corporation has verified the default bits states used during call progress All predefined settings provided by Teltone begin with a All others listed without the will be those created by the user User Define ...

Page 49: ...ol is chosen on the Type tab This allows the assignment of the channel protocol without having to go to the Signaling tab each time Undo Changes Button The Undo Changes button sets the signaling back to the predefined protocol listed before checking the User Define button The same thing can be done by clicking the down arrow for the predefined protocols and choosing one Save As Button The Save As ...

Page 50: ...ew control set select New on the Control Sets menu The New Control Set Name dialog box is displayed Enter a name and click OK The Control Set dialog box is displayed see Figure 25 Figure 25 Control Set Control Set Type Field The Control Set Type field is used to configure the mode the Edge will be in Note the Control Set Type defaults to Call Originate Call Originate Control Set Type The Call Orig...

Page 51: ...led control set can route a call to any other channel within the same control set when it receives the telephone number assigned on the Channels tab of the Unit screen Dialed control sets have the option to use up to two different Templates allowing Analog POTS channels and T1 E1 channels or two different T1 E1 channel types to be combined in the same control set Note When using the Dialed control...

Page 52: ... to DS0 Control Set Connects two channels together with no signaling The DS0 to DS0 Control Set only allows the use of a template created for T1 E1 Clear Channel protocol This can be done on a Single T1 E1 by connecting a channel to another channel on the same T1 E1 or on the Dual T1 E1 module connecting a channel from the Port 1 T1 E1 to a channel on the Port 2 Note Fractional T1 and T1 data is n...

Page 53: ...or example assume that for an Analog LS Channel Type the name Analog LS was given to the template Notice that in the Channel Assignment screen on the left side under Available Channels the template name Analog LS is displayed see Figure 26 Listed underneath are the channels that can be used for the selected control set and template For another example assume that the template was configured for T1...

Page 54: ...ng the channels Click OK once the channels have been chosen This will take you back to the Control Set screen see Figure 25 Start and Stop The Start and Stop areas on the Control Set screen are only used in Call Originate mode This is used to control when the Edge will start making test calls at what interval in seconds if any each call will be placed and when to stop placing the calls Start For s...

Page 55: ...The Number of Calls option is used to set a specific number of calls to be placed to each of the channels assigned Selecting Manual stops the test when the Control Set Enable button is disabled End to End Example The control set for end to end operation is configured with two template fields For this example we will use Switch Emulation with POTS and T1 Channels 1 Go to Control Sets menu and choos...

Page 56: ...P Edge User s Manual 40 400 00065 Rev E 46 Figure 28 End to End Control Set Example 5 Click the Edit Channels button The Channel Assignments dialog box appears See Figure 29 Figure 29 Connecting Channels ...

Page 57: ...bles 7 Click the End to End Example button The control set is activated allowing calls to take place The equipment under test at both ends initiate the traffic and the Edge is passive in this example Control Set Configuration Summary 1 Create a new control set by selecting New on the Control Sets menu 2 Select a Control Set Type 3 Assign template s to be used with the channels tested Select a temp...

Page 58: ...w menu Alerts Tab When an error or alarm status on any connected unit occurs the Edge configuration software can display a pop up window and or play a sound file see Figure 30 Figure 30 Alerts Tab Upgrades Tab The Upgrades tab see Figure 31 is where you enter license codes for Enabling additional purchased software modules Setting warranty information to view current warranty expiration date see V...

Page 59: ... s serial number on the bottom of the unit Your name and title Your company name address and telephone number Your email address this allows us to quickly send you your license code Once you have received a license code from Teltone select Options on the View menu Then select the Upgrades tab select the unit name in the Unit Name list enter the code and click the Install button License codes need ...

Page 60: ...refore are not associated with any template These signaling states are used as the defaults when selecting a new card mode in the Unit screen for an Edge and may be overridden on a per unit basis see T1 Card Mode on page 24 and E1 Card Mode on page 26 You can select an idle signaling state associated with a particular protocol or define the actual bit pattern directly Figure 32 Setting the Default...

Page 61: ...mation section See Figure 33 The same can also be done for all the other components on the display tree A simulation is started by clicking the Control Set Enable button The button appears depressed when enabled and a small running icon appears next to the Control Set name in the tree display see Icons on page 16 Upon completion of a timed simulation the changes to a finished Manually stopping the...

Page 62: ...s to an off hook See Figure 34 This is the state of the equipment under test On T1 E1 Wink Start operation there is no ringing or Ringing Status due to the nature of the protocol operation An off hook or on hook from the equipment under test is the only indication Event Log An event log is created for all events and calls related to the Edge Various filters can be turned on to eliminate conditions...

Page 63: ...information stored in both the Events and Calls log and starts the log with a clean slate Print allows printing of the current view of the log file Export allows saving the current view of the event log as a comma delimited text file The bottom of the screen has a Select section where filters can be used to display specific Events and or specific IDs of the Edge system The Event filter allows view...

Page 64: ...en running tests see Figure 36 This view shows the date time and ID plus the Time to Answer Call Duration and Disposition indicating if the call was answered or not Figure 36 Calls View on Event Log When viewing Calls a Summary box displays the dispositions and total number of all calls on the channels selected in the Select field ...

Page 65: ...nel or choose by the Control Set name Figure 37 Select Diagnostic Channels Screen Figure 38 shows how channels are displayed A box represents each selected channel Figure 38 Diagnostics Window Channels can be viewed in any combination To add other channels select View Channel on the Diagnostics menu To close a specific channel click the Close button in the title bar for the channel To close all th...

Page 66: ...ook buttons To view the signaling bits states for T1 E1 channels click the Monitor button for the channel For ESF framing and E1 the ABCD bit states are indicated For D4 framing the bit states are indicated in ABAB format Only one channel can be monitored at a time To exit Diagnostics select Exit on the Diagnostics menu Trace The step by step call progress of a channel can be displayed with the Tr...

Page 67: ...ser s Manual 40 400 00065 Rev E 57 Note To have the transmit and receive signaling bits visible in the Trace screen the same channel must be selected in the Diagnostics screen and have the Monitor button selected ...

Page 68: ...tions Note Sample programs that demonstrate the TAI functions are included in the TAI folder with the Edge software Important TAI features require using version 2 6 or greater of the Edge software Basic Operation Project files must be created using the Edge configuration software prior to using the TAI functionality The TAI interface does not allow for the editing of projects The Edge configuratio...

Page 69: ...ay vary depending upon the actual programming language used Retrieving Retrieving data from the Edge configuration software through DDE uses a DDE request DDE requests require the following items Service The service for all Edge requests is Telecom Simulation Platform Topic The topic for all Edge requests is link Item There are three different item parameters used for the Edge These items are TSPD...

Page 70: ...d will become socket1 the second socket2 and the third socket3 All commands to the Edge configuration software are sent on socket1 Data returned from the Edge configuration software is sent as described in the following command descriptions Since the socket connections are assigned in the order that they are requested in the event that any connection fails all three must be closed and then re esta...

Page 71: ...by Item TSPEvents List of events Events delimited by linefeed TCP Returns Socket1 OK Command accepted Error Invalid parameter Socket2 List of warning messages Messages delimited by Socket3 List of events Events delimited by linefeed Notes When using the DDE link events and warning messages are buffered and sent when polled by the getmessages command The getmessages command is not required when usi...

Page 72: ...nnectstatus Unitname name of an Edge unit defined in the current project file Connectstatus 0 if connection to Edge is broken 1 if connection to Edge is OK T1ALARMS portname alarms Portname t1 e1 port unitname slot port Alarms 0 no alarms 1 Clock Sync 2 Red Alarm 3 Clock Sync Red Alarm TASK taskname enabled runstatus Taskname task control set name Enabled 0 task control set disabled 1 task control...

Page 73: ...Error Invalid parameter Complete Initialization complete TCP Returns Socket1 Same data as DDE link item TSPData Notes The working response is sent immediately after the command is received and before the initialization of the unit The complete is sent when the initialization of the Edge is completed If communicating via DDE and the Working response is received the user should repeat the DDE reques...

Page 74: ...nitname Description Lists what cards are installed in an Edge unit Parameter unitname Name of Edge unit DDE Returns Item TSPData Error Invalid parameter Cardnames List of card types one per slot delimited with linefeeds TCP Returns Socket1 Same data as DDE link item TSPData ...

Page 75: ...e Description Lists what channels are assigned to a task Parameter taskname Name of task control set DDE Returns Item TSPData Error Invalid parameter Channelnames List of channels unitname slot port channel delimited with linefeeds TCP Returns Socket1 Same data as DDE link item TSPData ...

Page 76: ...ev E 66 LISTFILES Format LISTFILES Description Lists the project files that are in the data subdirectory DDE Returns Item TSPData Filenames List of file names delimited with linefeeds TCP Returns Socket1 Same data as DDE link item TSPData ...

Page 77: ...mat LISTTASKS Description Lists the tasks control sets that have been loaded from the project file DDE Returns Item TSPData Tasks control sets names List of task control set names delimited with linefeeds TCP Returns Socket1 Same data as DDE link item TSPData ...

Page 78: ...ISTUNITS Format LISTUNITS Description Lists the Edge units that have been loaded from the project file DDE Returns Item TSPData Edge unit names List of Edge unit names delimited with linefeeds TCP Returns Socket1 Same data as DDE link item TSPData ...

Page 79: ...s the Edge configuration software DDE Returns Item TSPData Working Command accepted loading project file Error Invalid parameter Complete File load complete TCP Returns Socket1 Same data as DDE link item TSPData Notes The working response is sent immediately after the command is received and before the file is loaded The complete is sent when the file load is completed If communicating via DDE and...

Page 80: ...Starts or stops a task control set Parameters taskname Name of task control set to start or stop state 0 or Stop Disable task control set 1 or Start Enable task control set DDE Returns Item TSPData OK Command accepted Error Invalid parameter TCP Returns Socket1 Same data as DDE link item TSPData ...

Page 81: ...ate 0 Return channel to normal operation 1 Set channel to ringing state 2 Place channel Off hook 3 Place channel On hook DDE Returns Item TSPData OK Command accepted Error Invalid parameter TCP Returns Socket1 Same data as DDE link item TSPData Notes The channel must be assigned to a task control set and the state must be valid for the protocol in use Multiple channels may be set in diagnostic mod...

Page 82: ... channel unitname slot port channel DDE Returns Item TSPData OK Command accepted Error Invalid parameter TCP Returns Socket1 Same data as DDE link item TSPData Notes The channel must be assigned to a task control set Only one channel can be monitored at a time setting a new channel will disable monitoring of any previously assigned channel Bit state changes are sent as events ...

Page 83: ... of channel unitname slot port channel DDE Returns Item TSPData OK Command accepted Error Invalid parameter TCP Returns Socket1 Same data as DDE link item TSPData Notes The channel must be assigned to a task control set Only one channel can be set to display PRI events at a time setting a new channel will disable the display of PRI events on any previously assigned channel ...

Page 84: ...buttons which normally would have shown on the pop up message box 0 OK 1 OK Cancel 2 Abort Retry Ignore 3 Yes No Cancel 4 Yes No 5 Retry Cancel Type Type of message 0 NONE 1 Communication error 2 Hardware error 4 T1 alarm 5 Other Response Default response which was generated to this message 1 OK 2 Cancel 3 Abort 4 Retry 5 Ignore 6 Yes 7 No Notes When running the Edge configuration software warning...

Page 85: ...oting tool and may be ignored When using the DDE link events and warning messages are buffered and sent when polled by the getmessages command The getmessages command is not required when using the TCP link Events and warning messages are sent on sockets 2 and 3 automatically when they occur and are not buffered ...

Page 86: ...g 4 EventTypeInformation ID Unitname Unitname slot Unitname slot port Unitname slot port channel Category 0 Standard messages 1 PRI Send messages 2 PRI RCV messages Event See event numbers for the specific category Data1 See specific events Data2 See specific events Notes When using the DDE link events and warning messages are buffered and sent when polled by the getmessages command The getmessage...

Page 87: ...11 logT1AlarmSet7 T1 E1 Alarm Set Undefined 7 135 logRCVerror Receive Error 136 logNoPort No Serial Port Selected 137 logNoIP No IP Address Defined 138 logFTPFail Network Connection Failure 139 logTXFail Transmit Failure 140 logCardWrong Wrong card type in slot 141 logCardMissing Missing card in slot 142 logCardInvalid Invalid card type in slot 143 logPortInUse Serial Port Already In Use 144 logIP...

Page 88: ...CALL Incoming Call 165 C_BUSY Busy 166 C_INVALID Invalid Condition Dialed task control set with Dialtone Disabled 167 C_O_START_EE Call From Channel ConnectChannel 168 C_CONNECT Connect To Channel ConnectChannel 169 C_DIAL_TIMEOUT Dial Timeout 170 C_ANSWER Answer 171 C_COD COD 172 C_AUDIO Audio File Playback Start 173 C_DIAL_NOMATCH No Match For Dialed Number 174 C_ALERTING Alerting Channel Connec...

Page 89: ...EST 18 N_VOL_RQ VOLUME REQUEST 19 N_MAP_RQ MAP REQUEST 20 N_MIC_RQ MIC REQUEST 21 N_BCHAN_LOOP B CHANNEL LOOPBACK REQUEST 22 N_DCHAN_LOOP D CHANNEL LOOPBACK REQUEST 32 N_SUS_RQ SUSPEND REQUEST 33 N_REM_RQ RESUME REQUEST 36 N_MORE_INFO_RQ MORE INFO REQUEST 39 N_SUS_RS SUSPEND RESPONSE 40 N_REM_RS RESUME RESPONSE 48 N_PDL_RQ Parameter DownLoad REQUEST 49 N_BAP_RQ BACP REQUEST 50 N_ALERT_RQ ALERT REQ...

Page 90: ... N_SS_IN SUPPLEMENTARY SERVICES 32 N_SUS_CF SUSPEND CONFIRM 33 N_REM_CF RESUME CONFIRM 34 N_SUS_IN SUSPEND INDICATION 35 N_REM_IN RESUME INDICATION 38 N_KEYPAD_IN KEYPAD INDICATION 48 N_PDL_CF Parameter DownLoad CONFIRM 49 N_PDL_END Parameter DownLoad END 50 N_CONN_ACK_IN CONN ACK INDICATION 51 N_BAP_IN BACP 52 N_XMIT_ACK_IN Transmit Data Acknowledge 53 N_CALL_PROC_IN CALL PROCEEDING INDICATION 54...

Page 91: ...a connid 15 SPID_ERR err in term init rq 16 NO_CHAN_ERR no channel avail 17 FACILITY_IND Facility IE indication 18 NOTIFY_IND See NOTIFY_IND Cause1 19 INFO_RQ_IND See INFO_RQ_IND Cause1 20 TEI_REM_INFO TEI Removed information 21 SCREEN_UPDATE Update Screen after PDL 22 MISC_INFO Miscellaneous information 23 ISDN_MSG ISDN MSG HEX DUMP 24 PPP_ACTIVE PPP Active 25 PPP_UPDATE_PROF Update the PPP Profi...

Page 92: ...or Detected 49 LINK_READY Frame Relay Link Becomes Ready 50 LINK_NOT_READY Frame Relay Link Becomes Not_Ready 51 BIT_RATE_CHANGE Frame Relay Link Bit Rate Change 52 CAS_R2_GROUP_I_TO NE_RECEIVED last CAS Group I tone received 53 CAS_R2_GROUP_II_T ONE_RECEIVED last CAS Group II tone received 54 CAS_R2_GROUP_A_T ONE_RECEIVED last CAS Group A tone received 55 CAS_R2_GROUP_B_T ONE_RECEIVED last CAS Gr...

Page 93: ...Q 31 CAUSE normal unspecified 34 CAUSE no circuit channel available 38 CAUSE Network out of order 41 CAUSE temporary failure 42 CAUSE switching equipment congestion 43 CAUSE user information discarded 44 CAUSE requested circ channel not available 47 CAUSE resource unavailable unspecified 49 CAUSE Quality of service unavailable 50 CAUSE requested facility not subscribed 51 CAUSE bearer capability i...

Page 94: ...pe non existent or not implemented 98 CAUSE message not compatible with state 99 CAUSE information element non existent or not implemented 100 CAUSE invalid information element contents 101 CAUSE Message not compatible with call state 102 CAUSE Timer error 300 diag 111 CAUSE protocol error unspecified 118 CAUSE invalid calling party number 127 CAUSE cause unknown SIGNAL_IND Cause 1 Description 0 S...

Page 95: ...n ISDN 3 PROGRESS Origination address is non ISDN 4 PROGRESS Call has returned to the ISDN 8 PROGRESS In band info or appropriate pattern is now available 16 PROGRESS Destination not responding call reattempted 17 PROGRESS Treatment applied to call 18 PROGRESS Call proceeding 19 PROGRESS Call alerting at destination 20 PROGRESS Call connected at destination 21 PROGRESS Dialing 22 PROGRESS Disconne...

Page 96: ...NAL INFO Authorization 66 PROMPT FOR ADDITIONAL INFO Digits 67 PROMPT FOR ADDITIONAL INFO Terminal ID FEATURE_IND Cause 1 Description 0 FEATURE idle 1 FEATURE dialing or active 2 FEATURE incoming call offered 3 FEATURE held 4 FEATURE associated call active 16 FEATURE inactive 17 FEATURE active 18 FEATURE requested call offered 19 FEATURE parameter entry ...

Page 97: ...e unit you must purchase the TSP PRI software module After installing the license code for the module the first time you configure the unit for PRI operation you are prompted to select whether to license the unit for T1 PRI operation or for E1 PRI operation To enable both T1 and E1 Primary Rate ISDN you must purchase both the TSP PRI and TSP 2PRI software modules When you install the license code ...

Page 98: ...ock needs to be set to where one end is providing timing normally the PSTN while the other end is deriving clock from it usually the CPE The Internal clock setting is used when the Edge acts as the PSTN and provides the clocking to the equipment under test External Clock is used when the Edge acts as the CPE and clocks from the equipment under test i e if the Edge is set for Internal clock the equ...

Page 99: ...nels are present to compensate for when an all Zeros state exist when equipment is off which can lead to lost of synchronization on the T1 due to too many successive zeros PCM Encoding The Edge configuration software defaults to mu law PCM Encoding which is the North American standard for T1 PCM encoding refers to the process used to digitize the analog signal It is necessary to ensure this matche...

Page 100: ...ill simulate Figure 41 T1 PRI Card Mode PRI Tab Switch Type The options available are AT T 4ESS AT T 5ESS NT DMS 100 250 and US National ISDN These options cover the majority of the North American switch types Simulation This selection establishes the end the Edge simulates Select Network if the Edge simulates the central office Select CPE if the Edge simulates the Customer Premise Equipment ...

Page 101: ...igure 42 T1 PRI Card Mode Channels Tab Subaddress The Subaddress is an optional extension of the ISDN phone number available with Primary Rate ISDN Calling Number and Called Number The Calling Number and Called Number fields each has options for Type of Address and Numbering Plan which are displayed in the caller ID when sent to the equipment under test For Type of Address select Unknown Number Na...

Page 102: ... Edge supports a bearer capability of Speech or 3 1 kHz Audio When configured as a Network the Edge sends the Date Time information element as part of the acknowledge message in response to a Setup message The date is fixed as July 4 The time is initially specified as 12 00 AM when the Edge configuration software is started and increments from that time as the system operates The time does not inc...

Page 103: ...Also if a Dual E1 module and a POTS module are used the last 8 channels for 4 Channel POTS or the last 12 channels for 8 Channel POTS are unavailable on the second E1 Clock The Clock needs to be set to where one end is providing timing normally the PSTN while the other end is deriving clock from it usually the CPE The Internal clock setting is used when the Edge acts as the PSTN and provides the c...

Page 104: ... Coding AMI suffices if no DDS data exists on any of the E1 channels HDB3 is used when DDS data channels are present to compensate for when an all Zeros state exists when equipment is off This can lead to lost of synchronization on the E1 data stream due to too many successive zeros PCM Encoding For PCM Encoding the choices are mu law and a law For T1 mu law is the default This is the PCM encoding...

Page 105: ...gramming the PRI switch platform and the end the Edge will simulate Figure 44 E1 PRI Card Mode PRI Tab Switch Type The only option for E1 PRI is EURO ISDN Simulation This selection establishes the end the Edge simulates Select Network if the Edge simulates the central office Select CPE if the Edge simulates the Customer Premise Equipment ...

Page 106: ...ress Calling Number and Called Number fields see Channels Tab on page 91 Figure 45 E1 PRI Card Mode Channels Tab Once you have configured the parameters on the E1 PRI and Channels tabs see Templates on page 33 and Control Sets on page 40 for information about building simulations Note To select a E1 Primary Rate CPE or Network template for a control set and then assign channels at least one unit s...

Page 107: ...ule for testing and exercising an IVR system by developing a script where the Edge places a call then sends DTMF and detects voice Testing an IVR system for a bank could be done by scripting the following The Edge places a call into the IVR system The IVR answers and plays a recording of options and the number to press for each option For example pressing 1 provides bank hours and pressing 2 provi...

Page 108: ...tion used to build test scripts for your tests and functions ScriptBuilder creates a script s sequence of steps in a user friendly flow chart style Once a script is completed and saved it is invoked by a control set in the Edge configuration software To assign a script file to a control set you must save your script files ssc in the scripts folder For more information see Assigning a Script on pag...

Page 109: ... command The Go To START command is always the last command in a script As commands are added a number is automatically assigned and appears in the upper right corner of the command There is a maximum of 511 commands allowed in a script START ELSE and END IF commands are only placeholders and not real commands so they are not numbered and do not count towards the maximum When a command is selected...

Page 110: ...ou to reverse the last ten operations cut copy paste move delete and adding a command Navigation Window A navigation window is located in the bottom right corner of ScriptBuilder providing an overall view of the script and an easy method to jump to different areas of a script Clicking a point in the navigation window centers that point in the main window The currently selected command in the main ...

Page 111: ...for the conditions which were selected in the last executed Wait for Event s command Else An Else command is automatically added for each If command and is the branch that is executed when none of the conditions in the associated If and Else If commands are true There is no command button to add an Else command Else If The Else If works the same as the If command and is used to differentiate when ...

Page 112: ...nd of a call Disconnect Note The call counts in Edge configuration software depend upon the receipt of this message The following indicate a completed call Answer Connect To Channel The following indicate the reasons for an incomplete call Busy Dial Timeout No Match For Dialed Number Wink Delay Dial Start Timeout Wink Delay Dial End Timeout No Tip Ground Detected No Acknowledge Detected The follow...

Page 113: ...valid character is used This allows for comments to be added to the right of the numbers in the file Lines with no valid number are automatically skipped If a line contains the word Restart the file is reset to the beginning After executing this command a Wait for Event s should be executed with the Request for Control Number Completed option selected This should be followed by If and or Else If c...

Page 114: ...oute channel s line state changed option with the line state specified The line state options are RING OFFHOOK DISCONNECT ANSWERED IDLE and BUSY Signal Route Channel This command is used when the script is connecting channels within the Edge similar to Switch Emulation or Dialed Control Set Types The Signal Route Channel command is used to actively send a message to its specified Route Channel The...

Page 115: ...ropriate detector must be enabled prior to the event using the Detect Enable commands 2 A Wait For Event s Detector Available must follow to wait until the detector is ready to receive 3 An If command verifies the detector is available 4 Another Wait For Events s Detect Seen waits for the audio signal 5 Another If statement determines what tone was seen and determines the next command accordingly ...

Page 116: ...ct command is used to enable and disable the DTMF tone detector The detector must be enabled before DTMF tones can be identified by the Edge during an active call The DTMF detector can look for digits as specified in the script or for the phone number assigned on the Unit screen If looking for a string of digits more than one pair of Wait For Events DTMF Digit Seen and If DTMF Detect Seen commands...

Page 117: ...r the Silence time The Tone Detector must be disabled after each time it is used before a new detector may be enabled Broadband tone detectors recognize energy between 300 Hz and 3400 Hz Detector thresholds can be set from 6 dBm to 30 dBm in 1 dB steps and timers can be set from 0 s to 30 s in 20 ms steps Voice Detect The Voice Detect command is used to enable and disable the voice detector When t...

Page 118: ...le is reset to the beginning After executing this command a Wait for Event s should be executed with the Request for Phone Number Completed option selected This should be followed by If and or Else If commands with Request For Phone Number Completed selected to test for Number Received or End of Number List Found Send Number DTMF Send Number DTMF allows DTMF digits to be sent over the audio channe...

Page 119: ...User Script Dialed Dynamically paired Route Channels remain paired until both channels use a Post Current State command to indicate a Disconnect In a script a Connect Channels command is issued to connect the transmitter of a channel to the receiver of its Route Channel and the receiver of the channel to the transmitter of its Route Channel Either channel may initiate the process to disconnect A c...

Page 120: ...mal Dialed control set and allows for two templates and two scripts Channels are assigned in each template and any channel can dial any other in the control set If only one template and script are needed the second template should be set to None The User Script Fixed Pairs control set is similar to the Switch Emulation control set and requires two templates and two scripts Channels are assigned in...

Page 121: ...tware CD ROM provides sample scripts in the Sample Scripts folder which has subfolders containing various types of scripts and a readme txt file with details about the scripts Sample scripts are also available on the Teltone website www teltone com where new sample scripts may be periodically added To use the sample scripts copy them to the scripts folder on your PC ...

Page 122: ...unication error to the Edge you MUST INITIALIZE the Edge to re establish the connection On the PC software go to Units Initialize and select the name of the unit you are attempting to connect to Initialization takes place automatically if you edit a Unit Any Control Sets which were active within that unit will need to be disabled and then re enabled Problem Error message Cannot connect to unit nam...

Page 123: ... for the Edge To verify the Edge can be seen on the network go to a DOS prompt on the PC and type PING xxx xxx xxx xxx where xxx xxx xxx xxx is the IP address of the Edge and verify the Edge responds If the Edge does not respond but has an IP address configured and is connected to your network contact your network administrator Problem Error message Downloading the audio messages requires a networ...

Page 124: ...stalled card types do not match defined card types Solution 1 Power down the Edge and place cards into same card slots as defined in the current project 2 Redefine the card types in the Unit edit screen To do this all channels within the unit would need to be removed from control sets Icon Problem Error message Unit name requires a License Code to enable its operation Contact Teltone Corporation S...

Page 125: ...nternal clock and the other must be set for external clock 3 Verify the device connected to the T1 E1 port is not deliberately sending an alarm condition it may be in a diagnostic mode Once the alarm condition has cleared the light on the module will turn green and the red button on the tree display will turn green If not try going to Units and choose Initialize for the Edge unit being configured ...

Page 126: ... the Edge or the device connected to the Edge must be set for internal clock and the other must be set for external clock Problem Edge does not see calls generated by device connected to T1 E1 channel Solution 1 Verify T1 E1 is not in alarm 2 Verify that the channel is assigned to an appropriate control set and that the control set is enabled 3 Verify that the Channel Protocol for the template use...

Page 127: ...aterial Authorization number and shipping instructions When returning units provide the following information Unit model number unit part number and serial number obtained from the Unit ID label on the bottom of the unit Teltone RMA number All available fault information Complete shipping and billing address Repair purchase order Technical Assistance For technical assistance on this product call T...

Page 128: ...ends TSP PRI to include both T1 PRI and E1 PRI operations License code for TSP PRI must be installed into Edge before installing license code for TSP 2PRI TSP ATS Advanced Test Scripting software module Accessories 101 00484 01 Rack mount bracket kit includes 2 brackets and 8 mounting screws 713 00028 02 Simulator hard shell carrying shipping case 730 00039 03 Replacement AC power cord 742 00033 0...

Page 129: ... CommPort when unit is in T1 PRI mode Changed program to only allow control with Network connection when in T1 PRI mode This allows for enhanced messaging Calls originated in T1 PRI working intermittently Only 1 channel working when using two 4 channel POTS modules in system Addressed clocking issue when unit in External Clocking mode In PRI channel 23 on the port 2 of a dual had no audio path The...

Page 130: ...to TSP ScriptBuilder Added support for new POTS FXO module Increased script size from 255 to 511 steps Added Cut Copy Paste and Undo Enhanced GoTo operation Multiple GoTo commands can jump to the same label Increased update speed of ScriptBuilder interface when editing commands Greatly increased printing speed of scripts 3 6 Added E1 primary rate ISDN capability New software module Added user opti...

Page 131: ...RI problem with call confirm recognition when configured as CPE Changes to the TSP configuration software Changed authorization code scheme to use license codes instead Fixed problems in user interface for PCs configured for other countries Fixed the TSP configuration software so that PRI channels and FXO channels can be assigned to same Switch Emulation control set Changes to TSP ScriptBuilder Fi...

Page 132: ...han 8 seconds in length with a total combined length of 24 seconds or less will be downloaded into the TSP and stored in non volatile memory If any messages are longer than 8 seconds or the combined length exceeds 24 seconds some messages will be streamed to the TSP in real time over the network connection Simulator Activation Manual or timed Diagnostics Monitor and manual control of signaling sta...

Page 133: ... Current 20 mA minimum Battery Source On hook 60 VDC minimum Ringing Source 42 VAC Ring Cadence Cycles on cycle 2 S off cycle 4 S Ring Frequency 20 Hz Impedance 600 ohm Audible Ringback 440 Hz 480 Hz 12 dBm composite Dial Tone 350 Hz 440 Hz 12 dBm composite Busy Tone 480 Hz 620 Hz 12 dBm composite POTS FXO Interface Connector Standard RJ14 Ring Detect 40 VRMS minimum REN 0 0 Loop Current Detect 10...

Page 134: ...1 1 Canada CSA C22 2 No 1010 1 European Union EN61010 European Safety Requirements for Electrical Equipment for Measuring Control and Lab Use EMC United States FCC Part 15 Class A Canada CISPR 22 85 Class A European Union EN61326 Class A for Laboratory Equipment Telecom Only Applies to TSP 8PFXO 01 Module United States FCC Part 68 Certification Number US AHHMA00BTSPU8PFXO Canada Industry Canada CS...

Page 135: ...ion software only displays the timings that are appropriate to the selected protocol For details on how the timings are applied see Call Process Flowcharts on page 128 The following describes each timing parameter Originating Calls Wait For Seize Acknowledge Time Edge waits to receive a seize acknowledge after sending a seizure Wait For Delay Dial Start Time Edge waits to receive the beginning of ...

Page 136: ... the length of time the Edge will send dial tone before going to the next phase of the call In a dialed control set the length of time the Edge will send dial tone while waiting for the first digit Wait for Dialing Start In a Dialed Control Set type the time the Edge will wait for the first digit to be received from the equipment under test before timing out Inter digit Dial Timeout In a Dialed Co...

Page 137: ...determined by when the Edge receives on hook from the equipment under test Only applies to Call Originate and Call Terminate control sets Far End Disconnect Time Time the Edge delays after receiving an on hook from the equipment under test before it goes to an on hook state If the equipment under test goes back to an off hook state during this time the call will remain connected In Call Terminate ...

Page 138: ...dge starts playing audio message 3 Edge detects COD from equipment under test Disconnect to start of new call timer starts Note If Call Duration timer expires before detecting COD from the equipment under test the Edge will disconnect first 4 Disconnect to start of new call timer expires Edge ready to receive next call 1 If no Audio Message is programmed for the channel proceed directly to step 3 ...

Page 139: ...eed to step 6 4 Delay Before Message timer expires Edge starts playing audio message 5 Edge detects COD from equipment under test Disconnect to start of new call timer starts Note If Call Duration timer expires before detecting COD from the equipment under test the Edge will disconnect first 6 Disconnect to start of new call timer expires Edge ready to receive next call 1 DTMF dialing uses the DTM...

Page 140: ...ge detects on hook from equipment under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will send 850ms COD 7 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking f...

Page 141: ...r test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will send 850ms COD 4 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 3 5 Disconnect to start of new...

Page 142: ...Edge detects on hook from equipment under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 8 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looki...

Page 143: ...rom equipment under test the Edge will proceed to step 8 6 Delay Before Message timer expires Edge starts playing audio message 7 Edge detects on hook from equipment under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 8 Far end disconnect timer expires Disconnect to start of new call ti...

Page 144: ...on timer expires before detecting on hook from the equipment under test the Edge will send disconnect first 4 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 3 5 Disconnect to start of new call timer expires Edge ready to receive next call...

Page 145: ...nt under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 6 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 5 7 Disconnect to sta...

Page 146: ...dge detects on hook from equipment under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will send 850ms COD 7 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking ...

Page 147: ...r test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will send 850ms COD 4 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 3 5 Disconnect to start of new...

Page 148: ...g audio message 3 Edge detects on hook from equipment under test Disconnect to start of new call timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 4 Disconnect to start of new call timer expires Edge ready to receive next call 1 If no Audio Message is programmed for the channel proceed directly to step 3 Call Setu...

Page 149: ...age timer expires Edge starts playing audio message 4 Call Duration timer expires Disconnect to start of new call timer starts 5 Disconnect to start of new call timer expires Edge ready to receive next call 1 DTMF dialing uses the DTMF Transmit Length timing for both the on and off times 2 If no Audio Message is programmed for the channel proceed directly to step 4 Delay Before Message TSP Plays A...

Page 150: ...e detects on hook from equipment under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will send 850ms COD 7 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking fo...

Page 151: ... test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will send 850ms COD 4 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 3 5 Disconnect to start of new ...

Page 152: ... starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 6 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 5 7 Disconnect to start of new call timer expires Edge read...

Page 153: ...t under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 6 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 5 7 Disconnect to star...

Page 154: ...ent under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will send 850ms COD 7 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 6 8 Disconnect to star...

Page 155: ...e Message timer expires Edge starts playing audio message 6 Edge detects on hook from equipment under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will send 850ms COD 7 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Fa...

Page 156: ...k from equipment under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 8 Far end disconnect timer expires Disconnect to start of new call timer starts Note If equipment under test goes back off hook before the Far End Disconnect timer expires the Edge goes back to looking for step 7 9 Dis...

Page 157: ...r test the Edge will proceed to step 8 6 Delay Before Message timer expires Edge starts playing audio message 7 Edge detects on hook from equipment under test Far end Disconnect timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 8 Far end disconnect timer expires Disconnect to start of new call timer starts Note If...

Page 158: ...ng audio message 3 Edge detects on hook from equipment under test Disconnect to start of new call timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 4 Disconnect to start of new call timer expires Edge ready to receive next call 1 If no Audio Message is programmed for the channel proceed directly to step 3 Delay Be...

Page 159: ...efore Message timer expires Edge starts playing audio message 3 Edge detects on hook from equipment under test Disconnect to start of new call timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 4 Disconnect to start of new call timer expires Edge ready to receive next call 1 If no Audio Message is programmed for th...

Page 160: ...ge timer expires Edge starts playing audio message 5 Edge detects on hook from equipment under test Disconnect to start of new call timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 6 Disconnect to start of new call timer expires Edge ready to receive next call 1 If Ringback is disabled in template proceed directl...

Page 161: ... Before Message timer expires Edge starts playing audio message 3 Edge detects on hook from equipment under test Disconnect to start of new call timer starts Note If Call Duration timer expires before detecting on hook from the equipment under test the Edge will disconnect first 4 Disconnect to start of new call timer expires Edge ready to receive next call 1 If no Audio Message is programmed for ...

Page 162: ...e 4 Ground 5 N C 6 N C Figure 50 Console Port Pin out Serial Cable and Adapters RJ11 Plug 1 RJ11 Plug 2 1 6 2 5 3 4 4 3 5 2 Pin 1 Pin 6 RJ11 Plugs 6 1 Figure 51 Serial Cable RJ11 to RJ11 RJ11 DB9 DB25 1 N C 14 2 N C 16 3 5 7 4 3 2 5 2 3 6 N C 1 Figure 52 Serial Cable Adapters RJ 11 Jack 1 2 3 4 5 6 RJ 11 Jack 1 2 3 4 5 6 ...

Page 163: ...nsmit 3 Receive White Orange 2 Transmit 6 Receive Orange 3 Receive 1 Transmit White Green 4 4 Blue 5 5 White Blue 6 Receive 2 Transmit Green 7 7 White Brown Pin 1 Pin 8 RJ45 Plug 8 8 Brown Figure 54 Ethernet Cross Over Cable T1 E1 Ports RJ45 1 Receive Ring 2 Receive Tip 3 N C 4 Transmit Ring 5 Transmit Tip 6 N C 7 N C 8 N C Figure 55 T1 E1 Module Pin out RJ 45 Jack 1 2 3 4 5 6 7 8 RJ 45 Jack 1 2 3...

Page 164: ...hite Blue 6 6 Green 7 7 White Brown Pin 1 Pin 8 RJ45 Plug 8 8 Brown Figure 56 T1 E1 Cable POTS Ports POTS FXO Modules RJ14 1 N C 2 Channel 2 Tip 3 Channel 1 Ring 4 Channel 1 Tip 5 Channel 2 Ring 6 N C Figure 57 8 Channel POTS FXO Module Pin out POTS FXS Modules RJ14 1 N C 2 Channel 2 Tip 8 Channel Only 3 Channel 1 Ring 4 Channel 1 Tip 5 Channel 2 Ring 8 Channel Only 6 N C Figure 58 POTS FXS Module...

Page 165: ...TSP Edge User s Manual 40 400 00065 Rev E 155 Y Cable RJ14 RJ11 Jacks Channel 1 Channel 2 1 2 4 Tip 3 3 Ring 4 4 Tip 5 3 Ring Pin 2 Pin 5 RJ14 Plug 6 Figure 59 POTS Y Cable RJ 11 Jacks 1 2 3 4 5 6 ...

Page 166: ...f Hierarchical Digital Interfaces ITU Fascicle III 3 Recommendation G 704 General Aspects of Digital Transmission Systems Terminal Equipments Synchronous Frame Structures Used at Primary and Secondary Hierarchical Levels ETS 300 102 1 A1 Integrated Services Digital Network ISDN User network Interface layer 3 Specifications for basic call control ETS 300 102 1 Integrated Services Digital Network IS...

Page 167: ...lling System No one DSS1 protocol Signalling network layer for circuit mode basic call control ETS 300 403 2 Integrated Services Digital Network ISDN Digital Subscriber Signalling System No one DSS1 protocol Signalling network layer for circuit mode basic call control Part 2 Specification and Description Language SDL diagrams ...

Page 168: ...chnique that transmits data at 1 536 Mbps by inserting the pattern 00011011 with BPVs in the fourth and seventh positions wherever ones density requirements are not met by unmodified data This is used when digital data channels exist on the T1 BPV BiPolar Violation The presence of two consecutive one bits of the same polarity on the T carrier C bit The least significant bit of the 18th frame used ...

Page 169: ...s connection with another channel Also known as a nailed up end to end digital connection CLIP Calling Line Identification Presentation A supplementary service that provides the calling party s number to the called party Clock See Internal Clock and External Clock CO Central Office The location of the last major switching point in the PSN before the connection is made to the customer premise Compa...

Page 170: ...entification Service A feature of 800 and 900 number service where the dialed number is sent to the called party DS0 Digital Service Level 0 The standard definition of a single channel at 64 Kbps using PCM Pulse Coded Modulation used in a T1 circuit DS1 Digital Service Level 1 A signal stream comprised of 24 channels and one framing bit running at 8 kHz per frame 193 bits X 8 000 1 544 000 bps the...

Page 171: ...ed interface modules card configuration and some channel options End to End Mode In this mode calls are placed through the TSP Edge Calls are originated on one end and are terminated on the other end by connecting one Edge channel to another Calls are initiated by an external device connected to the Edge and make a connection to another external device ESF A T1 framing type Extended Super Frame a ...

Page 172: ...l from the CPE GUI Graphical Unit Interface A generic name for any computer interface that substitutes graphics for characters HDB3 High Density Bipolar 3 A bipolar coding method that does not allow for more that 3 consecutive zeroes Immediate Dial Signaling protocol on a T1 E1 channel Accomplished by a change in the A and B signaling bits used in Robbed bit signaling operation Internal Clock This...

Page 173: ...nto the range Override The ability to access a networked Edge unit while it is in use This feature allows users to regain control of the Edge if the controlling PC loses its network connection PCM Pulse Code Modulation A method by which an audio signal is represented as digital data PCM Coding Options for T1 E1 parameter configuration in the Edge software POTS Plain Old Telephone Service the tradi...

Page 174: ...ggregate speed of 1 544 000 bits per second Transmit Digits DTMF digits that the Edge sends digitally to provide routing information as in DNIS operation for the equipment under test Upgrade Refers to adding software modules TSP PRI TSP 2PRI or TSP ATS to the Edge or to installing a more recent version of the Edge software Wink Start Digital T1 E1 channel protocol that uses an off hook condition t...

Page 175: ... Channel Assignments Analog 43 Screen 43 T1 Channels 43 Channel Configuration Wizard 32 Channel Identification 30 Channels Tab 29 Clock 24 26 88 93 Connecting to a Unit on the Network 21 Connections 12 Control Set Screen 40 CPE Simulation 35 90 95 D Diagnostics 55 Window 55 Dual T1 E1 Block End to End 3 Dual T1 E1 Module 6 E E1 Card Mode 26 E1 PRI Card Mode 92 Edge Configuration Software 14 End to...

Page 176: ... Safety Precautions ix ScriptBuilder 98 Serial Connection 13 19 Serial Number 49 Setup 9 Signaling Protocol 38 Signaling Tab Screen 38 Simulations CPE 35 90 95 Executing 51 Network 35 90 95 Programming 14 Viewing 52 Single T1 End to End 2 Slot Tab 23 Software Options 8 Software Installation 14 Software Modules Installing New 9 48 TSP 2PRI 9 87 TSP ATS 9 97 TSP PRI 8 87 Software Versions 20 Specifi...

Page 177: ...ooting 112 TSP 2PRI 9 87 TSP ATS 9 97 TSP PRI 8 87 U Unassigned Channels Default Idle State 50 Unassigned Channels Idle State 25 27 Units Configuration Summary 23 Information 22 Programming 18 Screen 18 Upgrades Tab 48 V Valid Module Combination 20 Versions 20 119 W Warranty 9 22 48 117 118 ...

Reviews: