TSP Edge User’s Manual
40-400-00065, Rev. E
41
assigned to the channel). For the Call Originate Control Set Type, one Template field
is displayed. All Channel Protocols except for T1/E1 Clear Channel can be used for
this Control Set Type.
Call Terminate Control Set Type
The Call Terminate Control Set is used when the Edge will receive calls generated by
the device under test. The Edge will answer calls placed into it, then play an audio file
after the call is connected (if an audio file is assigned to the channel). For the Call
Terminate Control Set Type, one template field is displayed. All Channel Protocols
except for T1/E1 Clear Channel can be used for this Control Set Type.
End-to-End Control Sets
The End-to-End Control Set is used when calls are placed by one connected device
through the Edge to another connected device.
There are four types of End-to-End Control Sets:
Dialed, Switch Emulation
,
Channel Bank
, and
DS0 to DS0
. With these operations the Edge passes traffic
through from one channel to another.
Dialed Control Set
- A Dialed control set acts as a PBX or Central Office switch.
Any channel within a Dialed control set can route a call to any other channel within
the same control set when it receives the telephone number assigned on the Channels
tab of the Unit screen.
Dialed control sets have the option to use up to two different Templates, allowing
Analog POTS channels and T1/E1 channels, or two different T1/E1 channel types, to
be combined in the same control set.
Note:
When using the Dialed control set type, the Templates used need to use
the Dialed Default Timing Set on the Type tab. This ensures proper operation
when making a call.
Switch Emulation Control Set
- Switch emulation control sets act similar to a
Dialed control set, except that instead of looking at the digits that are dialed, the
channels to be connected are pre-defined in the control set. This connection is
scripted and occurs automatically once a call is initiated by an off-hook or a seizure.
Note:
Calls routings are static and are not routed by telephone number, but by
channel assignment in the Control Set. For more information, see “Channel
Assignments” on page 43. Also, call progress including dial tone and ringback
is done by a scripted timing rather than action done by dialing a number.
Channel Bank Control Set
- Connects a T1/E1 channel to a POTS channel and
passes the signaling straight through. For Channel Bank operation, an Analog Loop