Inter-digit Dial Timeout
This only applies when the Template is used in a Dialed Control Set type. It’s the time allowed
between the dialing of digits before the TSP will timeout on the call.
Delay Before Ringback
In a Dialed Control set, the delay from the dialing of the last digit of a valid Phone Number to
when the TSP starts to send ringback. In other control sets, the delay from the end of dial tone to
when the TSP starts to send Ringback.
Ringback Length
Length of time the ringing cycle will be played by the TSP to the equipment under test. Applies
only to a Call Terminate Control Set.
All Calls
Delay Before Message
The delay before an audio file is played if one has been assigned to the channel. Does not apply
to End-to-End calls.
Call Duration/Disable Timeout
Controls the length of the call before the TSP starts a new call. Clicking on the box adjacent to
Disable Timeout will allow the call duration to be determined by when the TSP receives an
on-hook indication. Does not apply to End-to-End calls.
Far-End Disconnect Time
Time the TSP delays after receiving an on-hook from the equipment under test before it goes to
an on-hook state.
Disconnect to Start Of New Call
Time TSP delays after going on-hook before resetting for a new call.
Call Process Flowcharts for Analog LS, T1/E1 GS FXS or T1/E1 LS FXS
Figure 43 Call Terminate Analog LS, T1/E1 GS FXS, and T1/E1 LS FXS Flowchart
0
Off-hook by equipment under test.
1
Dial tone starts from TSP (if enabled on Template).
2
Dial tone ends.
3
Ringback start from TSP (if enabled on Template).
4
Ringback ends.
5
TSP starts playing message if programmed on Units screen.
6
Cut off disconnect (COD), .850s office open indication from TSP and/or on-hook from
equipment under test. COD occurs when the Call Duration timer expires only if the equipment
under test is still off-hook. Actual call duration is dependent on when the equipment under
test goes back on-hook.
7
TSP ready to receive next call.
Appendix 1 Flowcharts
40-400-00049, Rev. J
Page 59