Figure 25 Control Set Screen
The
Control Set
screen is used to choose the type of testing the TSP will do, the channels to be
tested and the protocol used for the channels.
Control Set Type Field
The
Control Set Type
field is used to configure the mode the TSP will be in. Note the
Control Set
Type
field in the example defaults to
Call Originate
. Clicking on the arrow next to Call Originate
will list all options available. They are,
Call Originate
,
Call Terminate
,
Channel Bank
,
Dialed
,
DS0
to DS0
, and
Switch Emulation.
Call Originate Control Set Type
The Call Originate Control Set is used when the TSP will be generating calls to the device under
test as discussed in the Operational Strategy section. For the
Call Originate
Control Set Type,
there will be one
Template
field displayed. All Channel Protocols except for
T1/E1 Clear Channel
can be used for this Control Set Type.
Call Terminate Control Set Type
The Call Terminate Control Set is used when the TSP will be receiving calls generated by the
device under test. The
Call Terminate
Control Set Type displays only one template field similar to
Call Originate. All Channel Protocols except for
T1/E1 Clear Channel
can be used for this
Control Set Type.
Programming the TSP
40-400-00049, Rev. J