Configuring the TSP Hardware/Software
Module Interface Matrix (Required Set-up)
Table 1 Module Interface Matrix
Slot count is 1-4 from left to right when looking at the back of the TSP.
Modules must be installed per the matrix before the TSP is powered on. Call setup scenarios that
are configured via the PC software are dependent upon the order in which modules are installed.
For example, configurations that are created when slot 2 has a T1/E1 module installed and slot 3
has a POTS module installed, will not be recognized as valid if the modules are moved to
different positions. Therefore it is always necessary to follow the required installation order
specified above. The TSP will give an error if the modules are not installed as required in the
matrix.
Basic Hardware setup
Before applying power to the TSP, install the optional modules per the matrix. Ensure they are
securely seated. Connect the CommPort cable (RJ-11 jack at both ends) to the unit at the jack
labeled Console. Connect the other end to the PC using the DB-9 or DB-25 adapter. For the
Ethernet connection, use the provided crossover cable (RJ-45 at both ends) if connecting directly
to the PC. If connecting to the network, a standard Ethernet cable will be needed.
Important
Before installing or removing a POTS module, connect a telephone set to any port of any POTS
module, power down the unit, and then go off-hook on the telephone set. This allows for voltage
dissipation from the base unit and prevents damage to the unit. An alternative procedure is to
power down the TSP for at least 30 minutes before installing or removing the module.
Power up the TSP
Before power-up ensure that the modules are seated firmly in the TSP to prevent damage.
The TSP uses a universal power supply that operates from 90 to 250 VAC, 43 to 63 Hz. Connect
the power cord and turn on the unit using the switch on the back of the unit.
Note:
Grounding is assured by using the appropriate (approved) power cord.
Page 8
Slot 1
Slot 2
Slot 3
Slot 4
One Single- or Dual-T1/E1 module
not used
T1/E1
not used
not used
One 4- or 8-Channel POTS module
not used
not used
POTS
not used
Two Single-T1/E1 modules (Note 1)
not used
T1/E1
T1/E1
not used
One Single- or Dual-T1/E1 module and one 4- or
8-Channel POTS module
not used
T1/E1
POTS
not used
Two 4- or 8-Channel POTS modules (Note 2)
not used
POTS
POTS
not used
Three 8-Channel POTS modules
POTS
POTS
POTS
not used
One Single- or Dual-T1/E1 module and two 8-Channel
POTS module (Note 3)
not used
POTS
POTS
T1/E1
One Single- or Dual-T1/E1 module and three 8-Channel
POTS modules (Note 3)
POTS
POTS
POTS
T1/E1
Note 1:
The TSP does not support two Dual T1/E1 modules.
Note 2:
If using both a 4-Channel POTS and a 8-Channel POTS module, Teltone recommends placing the 4-Channel POTS module in
Slot 2 and the 8-Channel POTS module in Slot 3.
Note 3:
A Single- or Dual-T1/E1 module can be used but only the second port of a Dual-T1/E1 module will be active if more than one
POTS module is installed. Port 1 of a Dual-T1/E1 module will be disabled.