Timings Tab
Timings are used to control the intervals of all the different parts of the call process while the TSP
is originating or terminating calls. The default times should be appropriate for most testing. These
timing controls can be changed while the
Template
is assigned to a
Control Set
(which will be
discussed in the
Control Set
section). The maximum value allowed on all parameters is 300
seconds. Clicking anywhere on the line for a parameter will highlight the value and bring up a
scroll bar (up and down arrows) to the right of the value. If you click to the left of the decimal
point, the scroll bar will increment/decrement by 1 second intervals. If you click to the right of the
decimal point the scroll bar will increment/decrement by .005 second intervals. You may also
enter the value directly. When doing so, the minimum increment allowed is .005 seconds and the
value entered will be rounded this way.
Figure 23 Timings Tab screen
There are three sections on the
Timings
screen,
Originating Calls
,
Terminating Calls
, and
All
Calls
.
Originating Calls
is used when the TSP will be generating calls in a
Control Set
.
Terminating Calls
is used when the TSP will be receiving incoming calls from the equipment
under test.
All Calls
has parameters that apply to both incoming and outgoing calls. All values are
in seconds. See Appendix 1 for a detailed description of each parameter.
All timings will reset to default settings by clicking on the
Defaults
button. (See Figure 23.)