1
Equipment under test answers before Wait For Answer timer expires
2
TSP starts playing message if programmed on
Units
screen
3
Equipment under test goes on-hook before Call Duration timer expires
4
TSP goes on-hook
5
TSP starts next call, go to 0
The TSP uses Calling Party Control. The equipment under test is the Called Party and can hang
up and pick up within the far end disconnect time without disconnect occurring
Timings Tab for E1 ITU Q.421
The
Type
tab for E1 ITU Q.421 has
DTMF Signaling Type
and the choices of
Ringback
enable/disable.
Figure 47 Timings Tab E1 ITU Q.421
The following section gives a brief description of all the parameters.
Originating Calls
Wait For Seize Acknowledge
Time TSP waits for seize acknowledge to occur after a seizure.
Delay Before Dial
The delay before the TSP starts transmitting digits for each call made by the TSP.
Wait for Answer
The time the TSP waits before abandoning a new call if there is no answer.
Appendix 1 Flowcharts
40-400-00049, Rev. J