3.2.1 Configuring directly via USB
To start programming the device, follow the instructions below:
Open the
ecoLINE PRO
programming software.
Select the USB option in the “
Connection type
” menu, power up the device
and connect it
to the computer using a USB A-B cable.
Enter the connection password.
o
Super administrator permission: full access to all settings. (Default password:
1234
).
o
Installer permission: can only access settings enabled by the super administrator.
o
Connecting without password: only restoring the factory default settings is available, if the
device has not been locked.
Click on the “
Connect
”
button.
If the wrong password is entered, the software connects to the device, but the same functions
will be available as when connecting without a password. To try a different password, close
the connection using the “
Disconnect
”
button, enter the new password and then
connect again using the “
Connect
”
button.
The software connects to the device using standard HID driver which is integrated in
Windows operating systems, thus there is no need to install special USB drivers. When the
device is connected to USB for the very first time, the Windows operating system installs the
drivers automatically.
The connection status is indicated by the USB status icon placed in the upper left corner of
the program window:
USB disconnected (green)
connected via USB (grey)
After connecting using the valid password, you can configure the device, change settings,
download event logs and monitor system status. The program will read the settings from the
device automatically after connecting to the device.
To close the connection, click on “
Disconnect
”
button.