29
Control by mobile app
:
Output control mode
: in this section you can configure the control mode of the output (or the
selected output 1 or 2 in case of the IN4.R2 model). Available options:
None
: the output will not be used.
Monostable
: the output will be activated for the time configured in the
“Duration”
section
of the output parameter settings, then it will revert to normal state automatically.
The duration can be configured from 100 milliseconds to 10 minutes.
Output parameter settings
: in this section you can configure the duration of the control impulse.
Click on the “
Edit
” button to open the parameter configuration window.
Controlled partition
: the contact output can be used to arm or disarm one partition of the alarm
system. In this field you can configure the number of the partition you want to control. The device
will monitor the configured partition only, and a status change will occur in the partition status
indicator found in the device and in the mobile application, only if arming or disarming occurs
specifically in the configured partition.
In case of a non-partitioned alarm system, the partition number may be 00 or 01, depending on
what partition number the alarm system sends in the Contact ID reports (you can check this in the
system logs found in the
Status monitoring
menu, when the alarm system reports an arming or
disarming event, e.g. CID: 1234183401
01
0010).