27
Input type
: the input can be normally open (
NO
), or normally closed (
NC
). When set to
NO
, event
is generated when the input circuit is closed, while when set to
NC
, opening the input circuit
generates an event. The input is closed when the given input
IN1…IN4
is shorted to
„
V-
” terminal (DC power negative) or to the
COM
terminal.
Sensitivity
: state changes of the input shorter than the value entered in this section with regard
to activation of the input are ignored by the device. The value can be configured from
200 milliseconds (0.2 seconds) to 60000 milliseconds (60 seconds).
Restore sensitivity / Unit of measure
: state changes of the input shorter than the value entered
in this section with regard to restoration of the input are ignored by the device. device.
The value can be configured from 200 milliseconds (0.2 seconds) to 60000 milliseconds
(60 seconds).
Remote monitoring settings:
Event code
: in this section you can configure the 3-digit Contact ID event code, which you want
to assign to the given input (e.g. 130 = burglar alarm). The event code consists of hexadecimal
characters (0..9,A,B,C,D,E,F). The device associates the event type (new event / restore) to the
event automatically, based on the configured input type (NO/NC) and the input state.
The software includes a built-in event code search tool, which contains the list of standard
Contact ID codes. The search tool can be opened by clicking on the
icon with the question
mark symbol, placed in front of the event code input field.
In the event code search tool you can search for events by name or by event code. For searching
by name, start typing the name of the searched event code in the field under the “
Specification
”
column header. For searching by event code, start typing the searched event code number in the
field under the “
Event code
” column header. The search tool will filter the list automatically
according to the hits. You can select an event code by clicking on it in the list, and then the program
will paste this automatically into the event code input field,
after clicking on the “
OK
” button.
Partition
: in this section you can configure the 2-digit partition number from 00 to 99, which you
want to assign to the given input.
Zone
: in this section you can configure the 3-digit zone number from 000 to 999, which you want
to assign to the given input.
Enable reporting to monitoring station
: using this checkbox, you can enable or disable
reporting of events generated by the given input to the remote monitoring station.