Genlock function.
You can enable the SDI output test signal to genlock to the
external reference signal by pressing the
CONFIG
button and selecting
Video/
Gen Outputs > Test Signal Genlock > Enable
. You can also use the CONFIG
menu to set the vertical and horizontal timing offsets used by the genlock
function. The genlock status icon in the Status Bar indicates the genlock status.
See
on page 40.
Dual link signals
The inputs for dual link signals are the same as for SDI signals. Dual Link
monitoring allows you to set up your instrument to monitor higher resolution
signals than can be monitored using the traditional single link input. Dual link
signals are combined in the instrument and then shown as a single signal on a
waveform or other display.
The instrument will automatically detect properly formatted dual link signals
which contain a SMPTE352 VPID in both links as required by SMPTE 372.
In this case, set the format, structure, and transport settings in the CONFIG > SDI
Input submenu to Auto to enable automatic detection of dual link signals.
If the SMPTE352 VPID is missing, the instrument may be forced into dual link
input mode by manually selecting the appropriate sample structure and transport
settings in the CONFIG > SDI Input submenu. Use the Video Session display
(
STATUS > Display Type > Video Session
) to verify proper configuration.
Alpha Channel information is visible if present and is available in RGB and
YCbCr display modes, but not in YRGB mode. The following figure is an
example of how the signal components appear.
Figure 7: Placement of dual link information in the Waveform display
Getting acquainted with your instrument
42
WFM2300 and WFM2200A Waveform Monitors User Manual
Summary of Contents for WFM2200A
Page 2: ......
Page 6: ......
Page 16: ...Table of Contents x WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 200: ...Functions 178 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 208: ...Software upgrades 186 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 242: ...ARIB content displays 220 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 252: ...Audio monitoring 230 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 270: ...Application examples 248 WFM2300 and WFM2200A Waveform Monitors User Manual ...