Elements of the SDI Status display.
Some elements are option dependent.
■
Signal
: Shows whether the signal is locked or not and shows the format of
the signal being monitored.
■
Jitter and Cable Loss Thermometers
: The horizontal bar graphs show your
measured values. 0-70% of the of the threshold value is represented by a
green area; 70-100% by a yellow area; 100-170% by a red area. The
measured value is shown as a black diamond.
■
Jitter1 HP Filter
: Sets the jitter high pass filter for one of the two jitter
engines that drive the EYE display. Selectable as: Timing (set to 10Hz);
Align (auto set to default filter settings); 10Hz; 1kHz; 10kHz; 100kHz. Jitter1
settings appear in tile 1 and 2.
■
P-P
: Shows the peak-to-peak jitter measurement, in time units and UIs (unit
intervals).
■
Cable Loss
: Shows the signal loss in dB, at the frequency specified in the
Cable Loss field of the Physical Layer Settings selection available from the
CONFIG button. This readout is blank when an ASI transport stream is being
monitored (Option ASI only).
■
Approx Cable
: Shows the approximate length of cable, assuming a
continuous run of cable of the specified type, as specified in the Cable Type
field of the Physical Layer Settings selection available from the CONFIG
button. This readout is blank when an ASI transport stream is being
monitored (Option ASI only).
■
Source Level
: Shows the calculated launch amplitude of the signal source,
assuming a continuous run of cable of the specified type, as specified in the
Launch Amplitude fields of the Physical Layer Settings selection available
from the CONFIG button. This readout is blank when an ASI transport
stream is being monitored (Option ASI only).
■
Cable Type
: Shows the cable type used to connect the signal source to the
instrument, as specified in the Cable Type field of the Physical Layer
Settings selection available from the CONFIG button.
■
Eye Amplitude
: Shows the amplitude of the eye waveform.
■
Eye Risetime
: Shows the rise time of the eye waveform.
■
Eye Falltime
: Shows the fall time of the eye waveform.
■
Eye Rise-Fall
: Shows the delta between rise time and fall time of the eye
waveform.
■
Eye Rise Overshoot
: Shows the percentage of rise time overshoot of the eye
waveform.
■
Eye Fall Overshoot
: Shows the percentage of fall time overshoot of the eye
waveform.
■
ASI Packet Size
: (Option ASI only) Shows the packet size in the transport
stream (188 or 204 bytes). The readout shows "Unlocked" when the signal
input is not ASI.
Display modes
130
WFM2300 and WFM2200A Waveform Monitors User Manual
Summary of Contents for WFM2200A
Page 2: ......
Page 6: ......
Page 16: ...Table of Contents x WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 200: ...Functions 178 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 208: ...Software upgrades 186 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 242: ...ARIB content displays 220 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 252: ...Audio monitoring 230 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 270: ...Application examples 248 WFM2300 and WFM2200A Waveform Monitors User Manual ...