Vertical Offset:
The timing difference between the reference and input
signal.
■
Horizontal Offset:
The timing difference between the reference and input
signal.
■
Relative to:
Indicates the chosen zero point for the timing display.
2
■
Link B to Link A:
Indicates the timing relationship between links of a Dual
Link signal.
Measure pop-up menu
(Timing Measure display)
Press and hold the MEAS button to open the Measure pop-up menu. The pop-up
menu enables you to save a timing setting so that you can measure the timing
between input or to match multiple inputs, and to specify the zero point of the
timing display.
Save offset.
Saves the timing of the current input as an offset to the timing
display. This saved timing becomes the zero point for the saved offset mode of
the timing display. This applies to both the cross-hair target in the middle of the
display and the numeric readouts.
The Save Offset function allows you to measure the timing between inputs or to
match multiple signals. Use the Relative To setting to select the definition for the
zero timing offset.
NOTE.
You cannot save the timing offset if either the input or reference is missing
or unlocked. You also cannot save a reference when in internal mode. Saving an
offset in these conditions would lead to misleading results so it is not allowed by
the instrument. A warning message appears on the screen if you attempt to save
the offset when it is not allowed.
2
If you select
Saved Offset
, you can save the timing from one signal, and then display the timing relative to that saved
offset.
Display modes
WFM2300 and WFM2200A Waveform Monitors User Manual
137
Summary of Contents for WFM2200A
Page 2: ......
Page 6: ......
Page 16: ...Table of Contents x WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 200: ...Functions 178 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 208: ...Software upgrades 186 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 242: ...ARIB content displays 220 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 252: ...Audio monitoring 230 WFM2300 and WFM2200A Waveform Monitors User Manual ...
Page 270: ...Application examples 248 WFM2300 and WFM2200A Waveform Monitors User Manual ...