Remote Control
5–16
MTD200 MPEG Test Decoder User Manual
*RST value:
MONitoring
Selects one of the three decoder modes:
MONitoring
Activates the monitoring mode. An applied transport stream
is monitored.
TRERror
Activates the ‘Trigger on Error’ function (refer to Com-
mands for the ‘Trigger on Error’ Function on page 5–35). If
the error condition set with CONFigure:TRERor:TRIGger
has occurred, a maximum of 800 transport stream packets
can be read with READ:TRERor?.
DUMP
Activates the ‘Dump’ function (refer to Commands for the
‘Dump’ Function on page 5–36). If the filter condition set
with CONFigure:DUMP:STATe and ...:TRIGger:PID has
occurred, a maximum of 1394 transport stream packets can
be read with READ:DUMP?.
Example: SENS:FUNC
MON
NOTE
. The TRERror and DUMP modes can only be activated by remote control.
Upon switchover from MONitoring to TRERror or DUMP, monitoring of the
transport stream is stopped (corresponds to command CONF:MON:CONT
STOP). When a switchover is performed from remote to manual control (refer to
Return to Manual Operation on page 5–3), the MONitoring mode is automati-
cally selected. If monitoring was active before the switchover to TRERror or
DUMP, monitoring will be continued when the MONitoring mode is selected
again.
On power up, the MPEG test decoder is always in the MONitoring mode.
Summary of Contents for MTD200
Page 1: ...User Manual MTD200 MPEG Test Decoder 070 9951 00...
Page 4: ......
Page 15: ......
Page 29: ...Introduction to Digital TV Transmission Technique 1 14 MTD200 MPEG Test Decoder User Manual...
Page 30: ......
Page 51: ......
Page 62: ......
Page 97: ......
Page 167: ...Remote Control 5 70 MTD200 MPEG Test Decoder User Manual...
Page 168: ......
Page 174: ...Maintenance and Checking 6 6 MTD200 MPEG Test Decoder User Manual...
Page 175: ......
Page 194: ......
Page 204: ...Glossary Glossary 10 MTD200 MPEG Test Decoder User Manual...
Page 205: ......
Page 209: ...Index Index 4 MTD200 MPEG Test Decoder User Manual...
Page 210: ......
Page 211: ......