TD-1/07-008
56 / 83
Default Value
: -
o
Zone5
Zone8
Address = 23 05-08
< IP >
Default Value
: -
8.3.5. Zone Trigger Delay
Zones don’t sense alarm until trigger delay expires.
o
Zone1 Trigger Delay
Address = 24 01
< IP >
To see value
:
LED
24 01 (wait)
LCD
2-
ZONE SETTINGS→ LOOP SETTINGS→ 01-ZONE DELAY (wait)
To change value
:
LED
24 01 R
R √
LCD
2-
ZONE SETTINGS→ LOOP SETTINGS→ 01-ZONE DELAY
R R √
R R = time(Trigger Delay = 30 ms x time)
Default Value
: 8 = 8x30=240 milliseconds=2.4 sec.
Example
:To set 1.zone trigger to 1.5 second do
“ 24 01
50
√ “
o
Zone2 Trigger Delay
Address : 24 02
< IP >
Default Value
: 8
.
.
.
.
o
Zone4 Trigger Delay
Address = 24 04
< IP >
Default Value
: 8
o
Zone5
Zone8 Trigger Delay
Address = 24 05-08
< IP >
Default Value
: 8
8.4. KEYPAD SETTINGS
8.4.1. Keypad Permissions
Keypad Permission address is 30 0X (X= Keypad address).Following table shows options in that address.
1.option(*)
Keypad
Enable/Disable
2.option
Quick Arm
3. option
Arm
4. option(*)
Disarm
5. option(*)
Programming
Permission
6. option
Access
7.option
Sabotage
Alarm
Enabled
ON
ON
ON
ON
ON
ON
ON
Disabled
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Note(*) : Theese options are assumed as enabled for the first Keypad (Keypad 1) even if they are disabled.
If sabotage alarm of Keypads (7. option in 30 0X) is ON, panel goes into alarm when its connection has lost.
o
Keypad 1 Permissions
Address = 30 01
< IP >
To see value
:
LED
30 01 (wait)
LCD
3-
KEYPAD SETTING → KEYPAD OPTIONS → 01-OPTIONS (wait)
To change Value
:
LED
30 01 S .......S
√
LCD
3-
KEYPAD SETTING → KEYPAD OPTIONS → 01-OPTIONS
S .......S √
S = multiple choice selection
Default Value
: 1=Keypad Enable, 2=Quick Arm Enable, 3= Arm Enable, 4=Disarm Enable,
5=Programming Permission Enable