TD-1/07-008
70 / 83
28
---
52 28
28-RESERVED
-
-
IP
29
---
52 29
29-RESERVED
-
-
IP
30
Custom Alarm (R)
52 30
30-CUSTOM EVENT
0000
Zone
IP
31
---
52 31
31-RESERVED
-
-
IP
32
Defaults Loaded
52 32
32-DEFS LOADED
0000
Type of Reset (3)
IP
Note
: (1) “(R) ” icon shows that restore code of event is automatically recorded and sent to CMS if it is selected in 51 XX.
(2) Special Arm/Disarm code is sent to Central Monitoring Station on Quick Arm, Arming on no activity, Automatic Arm/Disarm,
Arm/Disarm by key, Arm/Disarm by Remote Controller.
(3) Type of reset 1= Codes have been returned to factory defaults.
2= Panel Settings have been returned to factory defaults.
3= Both Panel Settings and Codes have been returned to factory defaults.
8.6.4. DTMF 4+2,etc Event Codes
These codes are sent to Central Monitoring Station. Use following table to enter or read hexadecimal data,
Enter
Read(VPC108)
A
1 (press long)
0 and 1
B
2 (press long)
0 and 2
C
3 (press long)
0 and 3
D
4 (press long)
0 and 4
E
5 (press long)
0 and 5
F
6 (press long)
0 and 6
Example: To enter
“ A3 “, press A(long) then press 3
While reading data, 0 and 1 (together) then 3 lights in VPC108 Keypad.
o
Intruder Alarm Code
Address = 53 01 . < IP >
To see value
:
LED
53 01 (wait)
LCD
5-COMMUNICATOR
→
53-4+2 CODES
→
01-INTRUDER ALM (wait)
To change value
:
LED
53
01 RR √
LCD
5-COMMUNICATOR
→
53 4+2 CODES
→
01-INTRUDER ALM
RR √
RR = event code
Example
: To set code as D1
do “ 53 01 4(long) 1 √ “
Note: If the second digit of event code is “0” , the following parameters in the table are sent to the CMS.
No
Event
Address
Menu
5-COMMNUNICATOR
→
4+2 CODES
→
Event Codes
Parameter
Prg
1
Intruder Alarm
53 01
01-INTRUDER ALARM
Zone
IP
2
Panic Alarm
53 02
02-PANIC ALARM
Zone
IP
3
Fire Alarm
53 03
03-FIRE ALARM
Zone
IP
4
Duress Alarm
53 04
04-DURESS ALARM
Zone
IP
5
Sabotage-Tamper Alarm
53 05
05-TAMPER ALARM
Zone
IP
6
Medical Alarm
53 06
06-MEDICAL ALRM
Zone
IP
7
Disarm by Duress
53 07
07-DURESS DISARM
-
IP
8
Disarm on Alarm
53 08
08- DISARM ON ALARM
-
IP