TD-1/07-008
14 / 83
3.8. POWER CONNECTION
Connect power cables properly to its place on panel case.
NOTE :
Don’t forget grounding.
There is AC 220V(230V)/16V 1,2A transformer inside Panel case. Connect 16V AC to panel and then you
will see green led lights on Panel. Connect battery cables to battery(be careful about poles). 2 unit 12V 7 Ah
battery can be connected to Panel. When battery voltage decrease to limit values, keypad goes into energy
protection mode so panel consumes lower energy.
Power terminal has a fuse of 0,125 A. If fuse breaks down, remove fuse from power terminal on panel case,
put the new one.
4. QUICK & SIMPLE PROGRAMMING
This section includes quick and simple programming of VAP404.
4.1. FIRST OPERATING
Control panel connections. If all connections are correct, connect AC voltage then connect battery. After
entering Date/Time,
Trouble
led is OFF on keypad if no other trouble on panel.
4.2. SIMPLE PROGRAMMING
o
Enter time and date. (Trouble message disappears.)
o
Enter User phone numbers, Central Monitoring Station phone numbers and account numbers.
o
Enter Codes.
o
Test siren.
o
Test Central Monitoring Station and User Phone Dialer
Default settings ; All zones are NC (Normally closed). Z1 is entry-exit zone, Z2 is follower zone, Entry and
exit delays are 15 sec. Installer code is 9999, master code is 1234, and Central Monitoring Station
communication format is Contact ID.
Description of simple installation is in the following. LED means LED Keypad, LCD means LCD Keypad.