TD-1/07-008
33 / 83
o
Doors can be armed by C button, windows can be armed by B button.
o
A (HOME) button arms zones except interior zones. Users can arm
panel while they are at home by using this button.
o
D(AWAY) button arm panel fully .
o
Zones except door, window, interior, exterior operates normally.
o
S.P.T uses entery/exit delay of 02 01/03 01.
o
S.P.T. disables zone partitions that are assigned before but
doesn’t
change settings.
o
Partition selection is done as following on S.P.T. 1= Interior, 2=
Window, 3= Door, 4= Exterior This selection can be done in 11
01(Siren Partitions), 10 03(Auto Bypassed Partitions), 10 07(ARM
Partitions), 12 01- 12 04 -12 07 (Auto Arm/Disarm Partitions), 13
XX(PGM Parameters),16 02 (Key Partitions), 31 0X(Keypad
Partitions), 43 XX(User Partitions),
Do following steps to use
S.P.T.
o
Set zone types; Door, Window, Interior, Exterior, Fire, etc..
22 XX page 56
Default Value: Z1 = Door, Z2= Interior, Z3= Interior, Z4= Interior
o
Select Enter/Exit zones and follower zones
23 XX page 57
Default Value: Z1 = Enter/Exit Delay, Z2= Follower Zone,
o
Assign enter and exit delay
02 XX, 03 XX page 39, 40
Default Value: Enter Delay= 15 seconds, Exit Delay =15 seconds
o
Enter user phone numbers
06 0X , page 41
o
Activate S.P.T.
1. option in 10 01 page 43
Default Value: S.P.T. = OFF
7.2. ACCESS CONTROL
VAP404 panel can be used as Access Controller. After user enters access code, locked door opens for the
specific time. User can use this code to Arm/disarm panel from other keypads if that user has permission.
Master user’s access permissions can’t be restricted. Do following steps to use Access Control ;
o
Connect PGM1 to door lock using relay
o
Connect button between PGM1 and GND to open door inside.
o
Select PGM1 output type(NC/NO). 2. option in 10 02
o
Select PGM1 type as Access Control
13 01address = 8
o
Select unlocking time
13 02 address = time
o
Connect keypad and assign its address
(Keypad 2, address = 2)
o
Select that Keypad as Access Controller
30 02 address: 1,2,3,4,6
o
Assign access code
07 01 address: 1111: 1.user
o
Select Keypads that access code is enabled
44 01 address: 2
7.3. USING VAP404 PANEL AS TWO SEPERATED PANELS
First, S.P.T. must be disabled.
For example ; if zone1 and zone2 are at A partition and zone3 and zone4 are at B partitions, Do following
steps ;
o
Connect two keypad and assign their addresses (Keypad1 : 1, Keypad2 : 2)
o
Connect 1.siren SRN output, 2. siren to PGM1 output
o
Assign zones to A anda B partition (1.zone=A, 2.zone=A, 3.zone=B, 4.zone=B) 2101 : 2, 2103 : 4
o
Select zone types
22 01- 04 addresses
o
Select Enter/Exit and follower zone of A partition
23 01- 02 addresses
o
Exit and follower zone of B partition
23 03- 04 addresses
o
Assign enter and exit delays of A partition
02 01, 03 01=times
o
Assign enter and exit delays of B partition
02 02, 03 02=times
o
Assign minimum 2 user code
07 01 and 07 02= codes
o
Assign user’s partitions
43 01 : 1, 43 02 : 2
o
Activate 2.keypad from Installer Program
30 02 : 1