TD-1/07-008
7 / 83
3. MOUNTING
WARNING! :
Don’t connect power to panel without finishing wiring.
3.1. GENERAL
Drill necessary holes on the wall and then mount panel case to wall by using proper holes. Metal cover of
panel constitute of body and cover. Cover is opened by removing two screws. Detectors, siren, and
telephone line are connected to Panel by using proper cables. (It is recommended to you use wire screened
cable or silver foiled LIYCY cable and ground the mains voltage) Before connecting supply voltage, make
sure that all connections are made correctly. Also it is recommended to connect keypad cable foil to panel
GND and keypad
GND. For the mains voltage connection, 3x0.75 mm² standard cable may be
usedDescriptions of panel terminals are in the following picture.
Following picture shows panel connections.