TD-1/07-008
48 / 83
Type
Description
Parameter
Def.
Value
10
PGM random output ON/OFF
Param.
PGM ON Time
PGM OFF Time
0
1...255 second
1...255 second
1
1...255 minute
1...255 minute
2
1...63 second
1...255 second
3
1...63 minute
1...255 minute
0
11
PGM is activated on ARM
The working time between 0...255 as minute.
Note:
If the number is 0, it works until closing by another source.
0
12
PGM is activated on DISARM
The working time between 0...255 as minute
Note:
If the number is 0, it works until closing by another source.
0
13
PGM is activated on RC panic
button
The working time between 0...255 as minute.
Note:
If the number is 0 and when the button is pushed the mode
changes.
0
14
PGM is activated on relevant
alarm occour
The table values of the
selected alarms are
added to each other
and entered.
Exp:
For Intruder and Fire alarms 1+4=5 is entered.
Alarm
Value
Alarm
Value
Intruder
1
Duress
8
Panic
2
Tamper
16
Fire
4
Medical
32
63
(*)9. option is valid for the first four PGM’s(PGM1 to PGM4)
o
PGM 1 Usage
Address = 13 01
< IP >
To see value
:
LED
13 01 (wait)
LCD
1-PANEL SETTINGS
→
PGM SETTINGS
→
USE PGM 1 AS: (wait)
To change value
:
LED
13 01 R √
LCD
1-PANEL SETTINGS
→
PGM SETTINGS
→
USE PGM 1 AS:
[ VALUE]
(Select using B(left) and C(right) buttons) √
R = Number between 0 and 10 (on LED Keypad)
Default value
: 0, Closed
Example
: To assign PGM1 to zones 13 01
1
√
o
PGM 1 Parameters
Address = 13 02
< IP >
To see value
:
LED
13 02 (wait)
LCD
1-PANEL SETTINGS
→
PGM SETTINGS
→
PGM 1 SETTING (wait)
To change value
:
LED
13 02 R R R √
LCD
1-PANEL SETTINGS
→
PGM SETTINGS
→
PGM 1 SETTING
P P P √
PPP = Number between 0 and 255
Default Value
: 0
Example
: To configure p
arameter as 2
do
“ 13 02
2
√ “
o
PGM 2 Usage
Address = 13 03
< IP >
To see value
:
LED
13 03 (wait)
LCD
1-PANEL SETTINGS
→
PGM SETTINGS
→
USE PGM 2 AS: (wait)