TD-1/07-008
21 / 83
15 02
Answer Ring Count
1~20 times
5 times
53
IP, MP
16 01
KEY Settings
1. option= Enable(ON)/ Disable(OFF)
2. option= Pulse/ Continues Contact
Closed,
Pulse
53, 54
IP
16 02
KEY Partitions
1. option= A Partition
2. option= B Partition
3. option= C Partition
4. option= D Partition
A, B, C, D
54
IP
Look at pg.
34 for SPT
20 01
20 02
20 03
20 04
20 05-08
Zone Wiring
Z1
Z2
Z3
Z4
Z5-Z8
1. option= NC/NO (ON/OFF)
2. option= Single end of line resistor,
Double zone ON/OFF *
3. option= Double end of line Resistor,
Double zoneON/OFF *
4. option=
Zone Enable/Disable
(*)2, 3 must not be selected if no end of line resistor
will be used.
2, 3 must be selected in zone doubling.
You don’t need to activate zone doubling feature
of Z5, Z6, Z7, Z8 while using zone doubling.
Zone doubling feature can’t be used together
with zone expansion module.
1= ON
4= ON
54
IP
55
21 01
21 02
21 03
21 04
21 05-08
Zone Partitions
Z1
Z2
Z3
Z4
Z5-Z8
1. option= A Partition Note: If S.P.T. (Smart partition
2. option= B Partition Technology) is selected,
3. option= C Partition these settings can be
4. option= D Partition ignored.
A
55
IP
Look at pg.
34 for SPT
22 01
22 02
22 03
22 04
22 05-08
Zone Type
Z1
Z2
Z3
Z4
Z5-Z8
0 = Free
6 = Fire
1 = Door
7 = Panic
2 = Window
8 = Duress
3 = Interior
9 = Tamper(Sabotage)
4 = Exterior
10 = Medical
5 = 24 Hour
11 = Custom
Z1 : 1
Z2 : 3
Z3 : 3
Z4 : 3
Z5-Z8 : 3
56
IP
23 01
23 02
23 03
23 04
23 05-08
Zone Extra Settings
Z1
Z2
Z3
Z4
Z5-Z8
(ON/OFF)
1. option= End door YES/NO
2. option= Follower Zone YES/NO
3. option= Entry/Exit Zone YES/NO
4. option= Silent Zone YES/NO
5. option= Can not be bypassed manually YES/NO
6. option= Can not be Auto bypassed YES/NO
7. option= Cross Zone YES/NO
Z1: 3
Z2: 2
Z3: -
Z4: -
Z5-Z8: -
57
IP
ADDRESS
FUNCTION
VALUE
DEFAULT
VALUE
ENTERED
VALUE
PAGE &
PROGRAM
IP:Installer
MP:Master
24 01
24 02
24 03
24 04
24 05-08
Zone Trigger Delay
Z1
Z2
Z3
Z4
Z5-Z8
2~255, time = value*30 ms
15
58
IP
30 01
30 02
30 03
30 04
Keypad Permissions
1. Keypad
2. Keypad
3. Keypad
4. Keypad
1. option= Keypad Enable/Disable
2. option= Quick Arm Enable/Disable
3. option= Arm Enable/Disable
4. option= Disarm Enable/Disable
5. option= Programming permission Enable/Disable
6. option= Access Control ON/OFF
7.option= Sabotage Alarm Enable/Disable
1.keypad
1,2,3,4,5
Other
keypads
2,3,4
58
IP
31 01
31 02
31 03
31 04
Keypad Partitions
1. Keypad
2. Keypad
3. Keypad
4. Keypad
1. option= A Partition
2. option= B Partition
3. option= C Partition
4. option= D Partition
A, B, C, D
59
IP
Look at pg.
34 for SPT