TD-1/07-008
38 / 83
LCD
0-BASIC SETTINGS
→ EXIT DELAY → 01-PART EXIT DLY
w w w SECOND(S) √
w w w = exit delay(second) , (between 0 ~ 255 seconds)
Default value
: 15 seconds
Example
: To set exit delay of A partition to 20 seconds do
“ 02 01 20 √ “
o
Exit Delay of B Partition
Address= 03 02
< IP >
Default value
: 0 second
o
Exit Delay of C Partition
Address= 03 03
< IP >
Default value
: 0 second
o
Exit Delay of D Partition
Address: 03 04
< IP >
Default
: 0 second
8.1.4. Central Monitoring Station Account Numbers
If Panel will be connected to Central Monitoring Station, Account number is recorded in following address.
Panel can connect 2 different Central Monitoring Stations.
o
Account No 1
Address= 04 01
< IP >
To see value
:
LED
04 01 (wait)
LCD
0-BASIC SETTINGS
→ CMS ACCNT #’ S → 01-CMS ACCNT NO (wait)
To change value
:
LED
04 01] R R R R √
LCD
0-
BASIC SETTINGS → CMS ACCNT #’ S → 01-CMS ACCNT NO
R R R R √
R R R R = Account No
Default Value
: 0000
Example
: To set 1.Account No to
2234
do
” 04 01
2234
√ “
o
Account No 2
Address= 04 02
< IP >
To see value :
LED
04 02 (wait)
LCD
0-BASIC SETTINGS
→ CMS ACCOUNT #’ S → 02-CMS ACCOUNT NO (wait)
To change value
:
LED
04
02 R R R R √
LCD
0-
BASIC SETTINGS → CMS ACCOUNT #’ S → 02-CMS ACCOUNT NO
R R R R √
R R R R = Account No
Default Value
: 0000
Example
: To set 2. Account NO to
2234
do
“ 04 02
2234
√ “
8.1.5. Central Monitoring Station Phone Numbers
If you use 2 phone numbers of the same CMS, first number is recorded to address of 05 01, second number
is recorded to 05 03 and
Account number is recorded to address of 04 01.
Press [0] (long) to add
duration time. If you connect 2.CMS, first number is recorded to 05 02, second number is recorded to 05 04
and Account number of 2.Central Monitoring Station is recorded to 04 02. Look at addresses of 50 11-15 to
select Central Monitoring Station that messages will be sent. Press 0 (long) to delete phone numbers.
Note: Central Monitoring Station dialer
is enabled (1. option in 50 01) automatically when any of CMS
number ( 05 01
05 04 ) is entered.
o
Central Monitoring Station-1 (CMS-1) Phone Number
Address= 05 01
< IP >
To see value
: