If 7.opt ion in 50 01 is selected, panel cancels to call other phone numbers when taking confirmation(Each
partition needs take confirmation to cancel their own calls ).
If 8.option in 50 01 is selected, siren becomes silent after confirmation when panel calls user( panel
continues to be armed).
Address = 50 01
< IP >
To see value
:
LED
50 01 (wait)
LCD
5-COMMUNICATOR
→
GENERAL OPTIONS
→
GENERAL SETTINGS (wait)
To change value
:
LED
50 01 S........S √
LCD
5-COMMUNICATOR
→
GENERAL OPTIONS
→
GENERAL SETTINGS
S........S √
S= Multiple choice selection
Default Value
: All options are OFF
Example
: To enable Central Monitoring Station dialing do
“ 50 01
1(ON)
√ “
Note:
Central Monitoring Station dialing is enabled (1. option in 50 01) automatically when any of CMS
number ( 05 01
05 04 ) is entered. User phone dialing
is enabled (2. option in 50 01) automatically when
any of user phone number ( 06 01
06 06 ) is entered.
o
Dial Attempt
Address = 50 02
< IP >
To see value :
LED
50 02 (wait)
LCD
5-COMMUNICATOR
→
GENERAL OPTIONS
→
DIAL ATTEMPTS (wait)
To change value
:
LED
50 02 R
R √
LCD
5-COMMUNICATOR
→
GENERAL OPTIONS
→
DIAL ATTEMPTS
R R √
RR = Dial attempt number ( 1 ~ 15)
Default value
: 3
Example
: To set dial attempt to
5
do
“ 50 02
5
√ “
o
Central Monitoring Station(CMS) Answer Wait Time
Address = 50 03
< IP >
To see value
:
LED
50 03 (wait)
LCD
5-COMMUNICATOR
→
GENERAL OPTIONS
→
ANSWER WAIT TIME (wait)
To change value
:
LED
50 03 R
R √
LCD
5-COMMUNICATOR
→
GENERAL OPTIONS
→
ANSWER WAIT TIME
R R TIMES
√
RR = Ring Time between 10 and 60 in seconds
Default Value
: 30
Example
: To set time to 35 seconds do “ 50 03 35 √ ”
o
Central Monitorin Station(CMS) Periodic Test Report Period
Address = 50 04
< IP >
To see value
:
LED
50 04 (wait)
LCD
5-COMMUNICATOR
→
GENERAL SETTINGS
→
TEST INTERVAL (wait)
To change value
:
LED
50 04 R R
√
LCD
5-COMMUNICATOR
→
GENERAL SETTINGS
→
TEST INTERVAL
TT HOUR(S) √
TT = Periodic test time between 1 and 48 hours
Default Value
: 6