TD-1/07-008
41 / 83
8.2. PANEL SETTINGS
8.2.1. Panel Main Settings
o
Panel Settings
This address includes options about how panel operates generally. Meaning of options is in the following.
1. option
SPT- Smart
Partition
Technology
2. option
Quick Arm
3. option
Automatic
Siren Test
4. option
Arm/Disarm
from
foreign
Keypad
5.option
Extendable
Exit Delay
6.option
Double Hit
7. option
Daylight
Saving
Enabled
ON
ON
ON
ON
ON
ON
ON
Disabled
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Functions of Partition buttons change if SPT
(Smart Partition Technology)
is enabled. A(HOME) button
arms zones except interior zones. B(Window) button arms window zones. C(Door) button arms Door zones.
D(AWAY) button arms all zones.
Quick Arm
enables arming without user code(User press partition button long that he/she wants to arm).
If
Automatic siren test
is enabled, siren alarms for 2 seconds.
If
Arm/Disarm from foreign Keypad
is enabled, users arm/disarm his/her partitions without interested in
keypad partitions.
Exit delay is extended when enter/exit zone is active if
Extendable Exit Delay
feature is enabled.
If Double Hit feature is enabled, two alarms from the same zone within cross zone timer duration will cause
panel to go into alarm. Double Hit feature is affects only zones selected as Cross Zone.
If Daylight Saving feature is enabled, panel automatically adjusts system time for daylight saving changes.
Note: Daylight Saving feature is devolped for the European Standarts.
Address= 10 01 .
< IP >
To see value :
LED
10 01 (wait)
LCD
1-PANEL SETTINGS
→
GENERAL SETTINGS
→
01-PANEL OPTIONS (wait)
To change value
:
LED
10 01 S ........S √
LCD
1-PANEL SETTINGS
→
GENERAL SETTINGS
→
01-PANEL OPTIONS
S ........S √
S = Multiple choice selection(1
6)
Default Value
: 2(ON)= Quick Arm enabled, 3(ON)= Automatic siren test is enabled,
5(ON)= Extendable Exit Delay Enabled
Example
: To disable Automatic Siren test do
“ 10 01
3(OFF)
√ “
o
Output Types
SRN, PGM1, PGM2, ARM output types(NC/NO) are configured in this address. Meaning of options is in the
following.
1.option
2. option
3.option
5.option
ARM(siren)
PGM1
PGM2
SRN
ON
NC
NC
NC
NC
OFF
NO
NO
NO
NO
Address = 10 02
< IP >
To see value
:
LED
10 02 (wait)
LCD
1-PANEL SETTINGS
→
GENERAL SETTINGS
→
OUTPUT POLAR. (wait)
To change value
:
LED
10 02 S ........S √
LCD
1-PANEL SETTINGS
→
GENERAL SETTINGS
→
OUTPUT POLAR.
S ........S √