Nozzle/Tip Selection Chart Explanation
These columns
show flow rates at
various pressures.
These columns show droplet sizes for
different styles of spray nozzle at
given pressures. Use these columns
to choose the best nozzle style for
your application.
Just like a normal nozzle chart, these columns show speeds available at given rates. The
only difference is the range of values that corresponds to the range of flows available with
DynaJet IC7140.
Nozzle/Tip Size Selection Example
METRIC:
If the operator wants to apply 100 l/ha at 5 km/h, the operator would look in the 100 l/ha column, and find the row that shows 5 km/h with room
above and below to compensate for higher and lower speeds that may be experienced in the field. In this case a TT11001 at 4-6 bar will work very well.
US:
If the operator wants to apply 10 GPA at 3.0 mph, the operator would look in the 10 GPA column, and find the row that shows 3.0 mph with room
above and below to compensate for higher and lower speeds that may be experienced in the field. In this case a TT11001 at 60-70 psi will work very
well.
Nozzle/Tip Series Selection Example
The chart shows that a Turbo TeeJet (TT) nozzle will give very coarse (VC) to coarse (C) droplets in this pressure range, and a Turbo TwinJet (TTJ60)
will give Coarse (C) droplets. The benefit of the TT is that the operator could select droplets from VC to C all at the same rate and speed.
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
1
1.0
-
F
VC
-
-
-
-
1.7
5.5
1.1
3.7
0.8
2.8
0.7
2.2
0.6
1.8
1.5
1.5
-
F
C
-
-
-
-
2.0
6.7
1.3
4.5
1.0
3.4
0.8
2.7
0.7
2.2
2
2.0
-
F
C
-
-
-
-
2.3
7.7
1.5
5.1
1.2
3.8
0.9
3.1
0.8
2.6
3
3.0
-
F
M
-
-
-
-
2.8
9.4
1.9
6.2
1.4
4.7
1.1
3.7
0.9
3.1
4
4 0
VF
M
3 2
10 8
2 2
7 2
1 6
5 4
1 3
4 3
1 1
3 6
Tip Size
Gauge
Pressure
(Bar)
Tip
Pressure
(Bar)
30% Minimum Duty Cycle
Speed Range (km
125 l/ha
150 l/ha
T
T
I
50 l/ha
75.0 l/ha
100 l/ha
T
J60
XR
/XR
C
T
T
T
T
J
6
0
A
IT
T
J
6
0
T
T
I6
0
11001
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
20
20
-
F
C
-
-
-
-
1.2
4.2
0.8
2.8
0.6
2.1
0.5
1.7
0.4
1.4
0.4
1.2
0.3
1.0
0.2
0.8
0.2
0.7
30
30
-
F
M
-
-
-
-
1.6
5.3
1.1
3.6
0.8
2.7
0.7
2.2
0.5
1.8
0.5
1.5
0.4
1.3
0.3
1.1
0.3
0.9
40
40
-
F
M
-
-
-
-
1.8
5.9
1.2
4.0
0.9
3.0
0.7
2.5
0.6
2.0
0.5
1.7
0.4
1.5
0.4
1.2
0.3
1.0
50
50
-
F
M
-
-
-
-
2.0
6.5
1.3
4.4
1.0
3.3
0.8
2.7
0.7
2.2
0.6
1.9
0.5
1.6
0.4
1.3
0.3
1.1
60
60
-
VF
M
-
-
-
-
2.1
7.1
1.4
4.8
1.1
3.6
0.9
3.0
0.7
2.4
0.6
2.0
0.5
1.8
0.4
1.4
0.4
1.2
70
70
-
-
F
-
-
-
-
2.3
7.7
1.5
5.1
1.2
3.9
1.0
3.2
0.8
2.6
0.7
2.2
0.6
1.9
0.5
1.5
0.4
1.3
80
79
-
-
F
-
-
-
-
2.5
8.3
1.7
5.5
1.2
4.2
1.0
3.5
0.8
2.8
0.7
2.4
0.6
2.1
0.5
1.7
0.4
1.4
90
89
-
-
F
-
-
-
-
2.7
8.9
1.8
5.9
1.3
4.5
1.1
3.7
0.9
3.0
0.8
2.5
0.7
2.2
0.5
1.8
0.4
1.5
30 GPA
15 GPA
T
T
I
Gauge
Pressure
(PSI)
Speed Range (MPH)
T
J60
XR
/XR
C
T
T
T
T
J
6
0
A
IT
T
J
6
0
T
T
I6
0
5 GPA
7.5 GPA
10 GPA
12 GPA
20 GPA
17.5 GPA
30% Minimum Duty Cycle
Tip Size
Tip
Pressure
(PSI)
11001
25 GPA
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
1.5
1.3
-
M
VC VC UC UC UC
11.2
37
7.5
25
5.6
18.7
4.5
15.0
3.7
12.5
3.2
10.7
2.8
9.4
2.2
7.5
1.9
6.2
2
1.7
-
M
VC
C
XC
UC UC
13.0
43
8.7
29
6.5
22
5.2
17.4
4.3
14.5
3.7
12.4
3.3
10.9
2.6
8.7
2.2
7.2
3
2.6
M
M
C
C
VC
XC
UC
16.1
54
10.7
36
8.0
27
6.4
21
5.4
17.8
4.6
15.3
4.0
13.4
3.2
10.7
2.7
8.9
4
3.5
M
M
M
M
VC
XC XC
18.5
62
12.3
41
9.3
31
7.4
25
6.2
21
5.3
17.6
4.6
15.4
3.7
12.3
3.1
10.3
5
4.4
-
-
M
M
VC
XC
VC
21
69
13.8
46
10.4
35
8.3
28
6.9
23
5.9
19.7
5.2
17.3
4.1
13.8
3.5
11.5
6
5.3
-
-
F
M
C
VC VC
23
76
15.1
50
11.3
38
9.1
30
7.6
25
6.5
22
5.7
18.9
4.5
15.1
3.8
12.6
7
6.2
-
-
F
M
C
VC VC
25
82
16.4
55
12.3
41
9.8
33
8.2
27
7.0
23
6.1
20
4.9
16.4
4.1
13.6
Tip Size
Gauge
Pressure
(Bar)
Tip
Pressure
(Bar)
30% Minimum Duty Cycle
Speed Range (km/h)
175.0 l/ha
200 l/ha
250 l/ha
300 l/ha
125 l/ha
150 l/ha
T
T
I
50 l/ha
75.0 l/ha
100 l/ha
T
J60
XR
/XR
C
T
T
T
T
J
6
0
A
IT
T
J
6
0
T
T
I6
0
11006
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
20
17
-
C
XC
-
-
-
UC
6.9
23
4.6
15.4
3.5
11.6
2.9
9.7
2.3
7.7
2.0
6.6
1.7
5.8
1.4
4.6
1.2
3.9
30
26
-
M
VC
C
XC
UC UC
8.6
29
5.7
19.0
4.3
14.3
3.6
11.9
2.9
9.5
2.4
8.1
2.1
7.1
1.7
5.7
1.4
4.8
40
35
M
M
C
C
XC
UC UC
10.0
33
6.7
22
5.0
16.6
4.2
13.9
3.3
11.1
2.9
9.5
2.5
8.3
2.0
6.7
1.7
5.5
50
44
M
M
M
C
VC
XC XC
11.2
37
7.5
25
5.6
18.7
4.7
15.6
3.7
12.5
3.2
10.7
2.8
9.4
2.2
7.5
1.9
6.2
60
53
M
M
M
M
VC
XC XC
12.3
41
8.2
27
6.1
20
5.1
17.1
4.1
13.7
3.5
11.7
3.1
10.2
2.5
8.2
2.0
6.8
70
62
-
-
M
M
VC
XC
VC
13.2
44
8.8
29
6.6
22
5.5
18.3
4.4
14.7
3.8
12.6
3.3
11.0
2.6
8.8
2.2
7.3
80
71
-
-
M
M
C
VC VC
14.3
48
9.5
32
7.1
24
5.9
19.8
4.8
15.8
4.1
13.6
3.6
11.9
2.9
9.5
2.4
7.9
90
79
-
-
F
M
C
VC VC
15.1
50
10.1
34
7.6
25
6.3
21
5.0
16.8
4.3
14.4
3.8
12.6
3.0
10.1
2.5
8.4
30 GPA
15 GPA
T
T
I
Gauge
Pressure
(PSI)
Speed Range (MPH)
T
J60
XR
/XR
C
T
T
T
T
J
6
0
A
IT
T
J
6
0
T
T
I6
0
5 GPA
7.5 GPA
10 GPA
12 GPA
20 GPA
17.5 GPA
30% Minimum Duty Cycle
Tip Size
Tip
Pressure
(PSI)
11006
25 GPA
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
1
1.0
-
F
VC
-
-
-
-
1.7
5.5
1.1
3.7
0.8
2.8
0.7
2.2
0.6
1.8
0.5
1.6
0.4
1.4
0.3
1.1
0.3
0.9
1.5
1.5
-
F
C
-
-
-
-
2.0
6.7
1.3
4.5
1.0
3.4
0.8
2.7
0.7
2.2
0.6
1.9
0.5
1.7
0.4
1.3
0.3
1.1
2
2.0
-
F
C
-
-
-
-
2.3
7.7
1.5
5.1
1.2
3.8
0.9
3.1
0.8
2.6
0.7
2.2
0.6
1.9
0.5
1.5
0.4
1.3
3
3.0
-
F
M
-
-
-
-
2.8
9.4
1.9
6.2
1.4
4.7
1.1
3.7
0.9
3.1
0.8
2.7
0.7
2.3
0.6
1.9
0.5
1.6
4
4.0
-
VF
M
-
-
-
-
3.2
10.8
2.2
7.2
1.6
5.4
1.3
4.3
1.1
3.6
0.9
3.1
0.8
2.7
0.6
2.2
0.5
1.8
5
5.0
-
-
F
-
-
-
-
3.7
12.2
2.4
8.2
1.8
6.1
1.5
4.9
1.2
4.1
1.0
3.5
0.9
3.1
0.7
2.4
0.6
2.0
6
6.0
-
-
F
-
-
-
-
4.0
13.2
2.6
8.8
2.0
6.6
1.6
5.3
1.3
4.4
1.1
3.8
1.0
3.3
0.8
2.6
0.7
2.2
Tip Size
Gauge
Pressure
(Bar)
Tip
Pressure
(Bar)
30% Minimum Duty Cycle
Speed Range (km/h)
175.0 l/ha
200 l/ha
250 l/ha
300 l/ha
125 l/ha
150 l/ha
T
T
I
50 l/ha
75.0 l/ha
100 l/ha
T
J60
XR
/XR
C
T
T
T
T
J
6
0
A
IT
T
J
6
0
T
T
I6
0
11001
Summary of Contents for DYNAJET IC7 140
Page 1: ...DYNAJET IC7140 INSTALLATION SETUP USER MANUAL 98 05347 R1...
Page 73: ......