Minimum PWM
As minimum PWM is attained, it is represented with a flat spot on the
Turn Compensation graph. Indicating implement speed is too slow,
and several e-ChemSaver Solenoids are operating at the minimum
PWM, not allowing compensation for the turn rate.
Figure 6-20:
Minimum PWM
Minimum PWM Solution
If conditions allow, increase speed, or disable a smaller droplet size to
force a higher PWM.
Figure 6-21:
Minimum PWM Solution
Maximum PWM
As maximum PWM is attained, it is represented with a flat spot on the
Turn Compensation graph. Indicating implement speed is too high,
and several e-ChemSaver Solenoids are operating at the maximum
PWM, not allowing compensation for the turn rate.
Figure 6-22:
Maximum PWM
Maximum PWM Solution
If conditions allow, decrease speed, or disable a larger droplet size to
force a lower PWM.
Figure 6-23:
Maximum PWM Solution